WP#55 - Data Center Power System Harmonics
The Green Grid · Mietek Glinkowski, Lynn Simmons et al.
The Green Grid's 2013 white paper explains harmonics in data centre power systems, what they do and how to balance them against efficiency, and stresses that zero harmonics is not necessarily better.
On this page
Overview
WP#55 is a Green Grid white paper dated 15 October 2013. It is the joint work of a large author group that includes Mietek Glinkowski, Lynn Simmons, David Loucks and Ian Bitterlin.
The white paper covers what harmonics are in data centre power systems, what they do and how to balance them against efficiency. It appears to offer a general engineering and operational view of the subject. In data centres dominated by power-electronic loads, harmonics are a genuine design issue for power quality and equipment compatibility.
The paper's most notable caution is that managers often request lower harmonics without knowing what level is appropriate. The abstract states plainly that zero harmonics does not necessarily mean a better operating environment. Demanding an overly tight harmonic figure in a specification can therefore be the wrong target in terms of cost and efficiency. Limits: the full text was not read, so harmonic limits, measurement methods and filter solutions are absent from this record. IEEE 519 and IEC 61000-3-12 are recorded as related standards. For a designer its value lies in steering harmonic targets toward limits set at the point of common coupling.
Key points
- White paper dated 15 October 2013.
- Managers often request lower harmonics without knowing appropriate values.
- Zero harmonics does not necessarily mean a better operating environment.
- Explains how to balance harmonics with efficiency.
- Related standards: IEEE 519 and IEC 61000-3-12.
Using it in design
- Compare THDi and THDv against IEEE 519 limits at the PCC rather than demanding near-zero values.
- Flag generator and UPS compatibility when high-harmonic loads are on the generator.
- Justify the harmonic target in the specification together with efficiency and cost.
- Consult the paper itself and the related standards for exact limits and filter selection.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Review your power design in SoSo CAD
Inspect supply paths, equipment loads and UPS failure scenarios in one model.
Request a demo
Who should read it
Engineers designing data centre power systems and managers writing harmonic specifications.
Related standards
- IEEE 519
- IEC 61000-3-12
Publication details
- Authors
- Mietek Glinkowski; Lynn Simmons; David Loucks; Dusty Becker; Ian Bitterlin; Bill Campbell; Harry Handlin; Pamela Lembke; Tom Earp; Darrin LeRoy; Andrew Lynch; Stephen McCluer; Jim Spitaels
- Publisher
- The Green Grid
- Year
- 2013
- Document number
- WP 55
- Document language
- English
- Source type
- Industry body
- Access
- Citation only
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note
Download requires a free TGG account sign-in and is governed by The Green Grid Terms of Use; summary and facts from the public library landing page; full text not redistributed.
Citation
Mietek Glinkowski; Lynn Simmons; David Loucks; Dusty Becker; Ian Bitterlin; Bill Campbell; Harry Handlin; Pamela Lembke; Tom Earp; Darrin LeRoy; Andrew Lynch; Stephen McCluer; Jim Spitaels (2013). WP#55 - Data Center Power System Harmonics. The Green Grid. WP 55. https://www.thegreengrid.org/en/resources/library-and-tools/380-WP%2355---Data-Center-Power-System-Harmonics
Events on this subject
Browse the events calendarAll content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.