API and DCIM hand-off

Connect project data to your workflow. Create revisions and start calculation and export jobs.

Access and permissions

An organisation owner or administrator creates a read or read-and-write API token in settings. The token is shown once and expires within 365 days. Every request is subject to the user’s current role and licence entitlements.

Send the token in the Authorization: Bearer header. Each token allows 60 requests per minute. Retry-After on a 429 response gives the waiting time in seconds.

Request contract

POST requests require Idempotency-Key. Repeating the same key and content returns the original response; different content returns 409. Lists return items and nextCursor. The limit parameter accepts 1 to 100.

Errors return an error code and a message. lisans_modul_yok, lisans_limit and lisans_salt_okunur preserve the application’s licence decisions. Breaking changes use a new major-version path; removals are announced at least 180 days in advance.

DCIM hand-off package

A revision produces location, cabinet, equipment, power-connection and model tables. Data connections are included when the design contains network links. The ZIP contains CSV files, an Excel workbook, column definitions and a validation report. Unknown values remain blank and are listed in the report.

Upload headers from your CSV or XLSX template to map fields, constants and unit conversions. The dcTrack and Nlyte profiles are starter mappings based on common field names; verify them against the import template for your version. DCIM export uses the project_package entitlement.

API reference

Download the OpenAPI 3.1 document

curl https://app.sosocad.com/api/v1/projects \
  -H "Authorization: Bearer $SOSOCAD_TOKEN"

GET

/api/v1/projects

List projects

POST

/api/v1/projects

Create a project

name, description → 201

GET

/api/v1/projects/:id

Read a project

GET

/api/v1/projects/:id/revisions

List revisions

POST

/api/v1/projects/:id/revisions

Create a revision from a DesignDocument

label, design → 201

GET

/api/v1/projects/:id/revisions/:rev

Read revision metadata

GET

/api/v1/projects/:id/revisions/:rev/design

Read the design document

GET

/api/v1/projects/:id/revisions/:rev/calculation

Read the latest stored calculation, including its design hash

GET

/api/v1/projects/:id/revisions/:rev/schedules

Calculate physical schedules

GET

/api/v1/projects/:id/revisions/:rev/findings

Read stored findings and stale-decision metadata

GET

/api/v1/projects/:id/revisions/:rev/airflow-risk

Calculate bounded airflow risk

GET

/api/v1/projects/:id/revisions/:rev/cost-summary

Calculate cost summary with unknowns

POST

/api/v1/jobs

Start a calculation, report or export job

type, params → 202

GET

/api/v1/jobs/:id

Read job status

GET

/api/v1/files/:id

Download a generated file

Data centre events and new resources

Once a month: newly added sources, changes to Turkish regulations and upcoming data centre events.