Cutting workshops, board merchants, production engineers and series manufacturers.

Cutting and optimisation

Start with your cutting list. Evaluate plans against kerf, grain and machine rules, with material cost, reusable offcuts and the gap to a proven lower bound. When a design change can help, suggestions respect your locks and permitted limits.

Guillotine layouts and proven lower bounds

Generate executable cutting patterns for rectangular parts, determine how many boards each pattern requires and see the result’s gap to a proven bound.

Input
Part list, board stock, saw and machine profiles, material cost, objective priorities and effort setting.
Output
Board patterns, exact part quantities, utilisation and waste, cost, reusable offcuts, proven lower bound and gap.

Rules and parameters

  • Rules cover 2-, 3- or n-stage patterns, first-cut direction, kerf, four-edge trimming, head cuts, grain and rotation permissions per part.
  • Pattern generation establishes manufacturable geometry; pattern selection meets quantities. Pattern diversity and repetition are considered for stack cutting.
  • Material cost, waste, cutting time, machine movement, pattern count and offcut quality can use weighted or lexicographic objectives.
  • Every plan reports its proven lower bound and gap. A result is described as optimal only when the gap is zero; fast, balanced and deep effort settings use deterministic limits.
  • Manual moves, rotations and cut-order changes are validated live. Plans with overlaps or grain or guillotine-rule violations cannot be saved.

Default workflow

Upload a list, select the board and run the organisation’s cost-first profile.

Expert controls

Adjust stage count, objective weights, part priorities, stock restrictions, optional filler production and plan locks.

Correctness checks

A validator independent of the plan-generating code checks overlap, boundaries, kerf, guillotine structure, grain and quantities. Assessment uses OR-Library and ESICUP cgcut/gcut benchmarks, the lower-bound invariant and identical output for identical input.

True-shape nesting and grain matching

Nest curved and irregular parts using their actual contours while retaining grain continuity across adjacent doors and drawer fronts.

Input
Part contours and internal openings, material, cutter diameter, rotation angles, grain groups and defect zones.
Output
True-shape board layouts, utilisation and offcut reports, cutting geometry and plan comparisons.

Rules and parameters

  • No-fit polygon geometry excludes overlaps; nesting in suitable internal openings, free or stepped rotation and common-line cutting are considered.
  • Cutter diameter, inter-part spacing, defect zones, material and direction constraints belong to the layout.
  • Matched doors and drawer fronts remain adjacent and ordered on the board. Manually edited plans use the same validation rules.

Default workflow

Select contours and a machine profile, then solve with the standard nesting settings.

Expert controls

Adjust rotation angles, common-line cutting, internal-hole use, grain groups and part priorities.

Correctness checks

An independent geometry validator checks contour overlaps, spacing and direction; ESICUP irregular-shape sets and production lists provide comparison cases.

Offcut stock and linear cutting

Evaluate reusable offcuts alongside new boards and connect profiles, strips, skirting, edging and worktop lengths to the same production demand.

Input
Multiple stock sizes and quantities, offcut geometry and defects; length lists, kerf and angled cuts.
Output
Stock consumption, offcut reservations and labels, 1D cut plans, reusable remaining lengths and cost.

Rules and parameters

  • Offcut priority, reusable area or length thresholds, non-rectangular remnants and stock-quantity limits remain enforced.
  • The linear solver considers stock lengths, kerf and angled-cut requirements; remnants below the threshold are not counted as reusable stock.
  • Column-generation linear optimisation and board nesting produce consistent stock movements linked to material codes and order demand.

Default workflow

Select stock sizes and the offcut threshold, then solve the demand list.

Expert controls

Adjust offcut priority, stock-quantity limits, defect zones and angled-cut rules.

Correctness checks

Part quantities and consumed stock are independently calculated; linear plans are compared with published cutting-stock and bin-packing examples.

Design-for-manufacture dimension and material suggestions

See which dimension changes alter the cutting plan, with before-and-after results. Savings are calculated by cost item from the stated inputs and full-solver output.

Input
Production model, length/width/thickness locks, limits, increments, linked groups, permitted materials and annual quantities.
Output
Ranked suggestions, before-and-after plans, batch and annual impact, quantity sensitivity, accepted revision and change list.

Rules and parameters

  • Candidate dimensions come from threshold calculations: w = (U + k) / n - k, where U is usable length, k is kerf and n is the number of parts. Linked dimensions change together.
  • Suggestions can evaluate catalogue board sizes, approved materials for hidden parts, common-part standardisation and construction allowances.
  • Suggestions based on carton, pallet and equipment dimensions are compared by part variety, setup count, stock, edging, machining and packaging effects.
  • Individual and combined suggestions are shown only after full-solver validation. Locks and limits cannot be violated; claimed board savings depend on a change in board count.
  • Accept, reject and defer decisions retain a reason. Acceptance creates a new revision and updated drawings while preserving the original file.

Default workflow

Set the maximum permitted dimensional change and compare the first suggestions.

Expert controls

Manage locks, limits, suggestion types, objective weights and combined-suggestion count per part.

Correctness checks

Threshold formulas are compared with hand calculations and locked dimensions remain invariant. Re-solving an accepted revision checks that it reproduces the proposed result.

Edgebanding, cutting dimensions and sequence

Calculate cut sizes from finished dimensions for each edge, linking edging and adhesive consumption to machine sequence.

Input
PVC, ABS, acrylic, veneer or solid-wood edging; thickness, width, decor, roll length, adhesive and pre-milling allowance.
Output
Cut dimensions, edging length, roll-cutting plan, adhesive usage, edge sequence, machine program and label markings.

Rules and parameters

  • Edging thickness and pre-milling allowance are calculated separately for each finished edge.
  • Overlap sequence, corner rounding, curved edges and minimum bandable part sizes depend on the machine profile.
  • Start and end allowances, roll length, edging and adhesive changes inform part sequencing. Barcodes call programs; edging symbols stay consistent across drawings and labels.

Default workflow

Use decor-matched edging and the visible-edge rules.

Expert controls

Adjust edging per edge, processing order, pre-milling and machine limits.

Correctness checks

Cut sizes and lengths are checked against hand-calculated tables; minimum part limits use boundary cases and production sheets.

Fabric, leather and marker planning

Nest upholstery patterns while respecting nap, pattern alignment, quality zones and stretch direction.

Input
DXF and industry patterns, seam allowances, notches, grainlines, fabric rolls or digitised hide contours.
Output
Marker layout, ply and length plan, cutting-machine file, consumption and waste report.

Rules and parameters

  • Paired and mirrored parts, roll width, nap direction, stripe and check match points, and 0/180-degree or free rotation are enforced together.
  • Ply count, marker length, roll ends and defect markings determine fabric consumption.
  • Leather quality and defect polygons come from digitisation or manual marking and are checked against part-quality classes and stretch direction.

Default workflow

Load the patterns, select fabric or leather and generate the layout.

Expert controls

Adjust pattern-match points, part priorities and quality rules.

Correctness checks

Independent checks cover overlaps, direction, pattern alignment and quality zones. ESICUP garment/fabric sets and manufacturer markers provide consumption comparisons.

Cut-to-size service and sales counter

Price a customer’s list, add it to the cutting queue and deliver labelled parts.

Input
Part lists entered at the counter, imported from files or submitted by customers; tariffs and offcut-ownership choices.
Output
Layout-based price, cutting queue and delivery time, part labels, handover note and cost allocation by customer.

Rules and parameters

  • Board usage, cutting length, edging length and hole count have separate tariffs, with trade-specific prices and account links.
  • Returning offcuts to the customer or retaining them at the workshop affects pricing. Jobs combined on one board use an explicit allocation rule for total cost.
  • The customer order surface connects list entry, pricing and approval or payment flow to the counter queue, using the product’s pricing engine.

Default workflow

Enter the list, review the price and add the job to the queue.

Expert controls

Adjust tariffs, customer-job batching and offcut-ownership policies.

Correctness checks

Price is recalculated from the layout; costs allocated to customers must sum to the total job cost.

Common parts and waste across the product range

Measure common parts, setup demand and waste sources across the product range, beyond a single cutting plan.

Input
Product and part records, layout results, setups, suggestion decisions and recorded actual consumption.
Output
Common-part ratio, part variety, setup count, product and material waste trees, suggestion acceptance and recorded savings analysis.

Rules and parameters

  • Utilisation and waste trends remain traceable to source runs; products and parts creating the most waste are shown separately.
  • Realised savings are calculated only from recorded consumption and comparison inputs. CSV, Parquet and read-only data access carry the analysis into other tools.
  • This area analyses product-range engineering. Business delivery-performance, machine-load, sales and profitability dashboards belong to the ERP integration scope.

Default workflow

Review common-part, setup and waste indicators in the standard product-range view.

Expert controls

Define engineering metrics and data exports.

Correctness checks

Every indicator is recalculated from source part, plan and consumption records; totals are compared with record-level values.

Discuss your production workflow

Tell us about your cutting lists, materials and machines. We will prepare the discussion around the inputs you use and the outputs you need.