Production engineers, technical draughtspeople and teams working with specialist materials.
Engineering
Connect the part list to manufacturability. From hole spacing and shelf deflection to coating consumption and glass orders, each calculation retains its inputs, limits and output in the same production model.
Drilling, grooves and manufacturability
Turn hardware and construction rules into machining features for each part, exposing machine limits before program generation.
- Input
- Production model, hardware patterns, construction rules, tool and machine limits.
- Output
- Holes, grooves, pockets, contours, profiles and cuts with face, datum corner and direction data; manufacturability findings.
Rules and parameters
- Features include vertical and horizontal hole diameter, depth and countersink; grooves, rebates, pockets, chamfers, radii, angled cuts, sink, hob, handle and cable openings.
- System 32 rules cover a 32 mm pitch, 37 mm front offset and 5 mm holes, alongside hinge-cup, slide, dowel and shelf-pin templates.
- Six faces, datum corners, mirrored pairs and turnover steps are tracked. Manually added and locked features survive rule recalculation.
- Checks cover hole collisions, remaining material, tool access, internal radius, depth, edge-banding sequence and machine working envelope.
Default workflow
Review the rule-generated machining features in the part view.
Expert controls
Adjust grids, edge distances and machining templates; add, move, lock and map features to machines.
Correctness checks
Verification uses independent geometry checks, reference values from manufacturer drilling patterns and comparisons with production part drawings.
Structural prechecks and ergonomics
Review shelf and top deflection, fitting loads, overturning and user reach during design. Structural results are prechecks and do not replace testing or certification.
- Input
- Product family, intended use, load cases, spans, thicknesses, material properties and user dimensions.
- Output
- Deflection and moment calculations, fitting and hanging loads, fixing alerts, test plan, technical file and 3D reach violations.
Rules and parameters
- Loaded and unloaded cases with open doors or drawers are assessed with wall-fixing tension and overturning moment.
- Rule-set scope includes EN 14749 and EN 16121/16122 for storage; EN 12521, EN 15372 and EN 1730 for tables; EN 12520, EN 16139 and EN 1728 for seating; EN 527/1335 for offices; and EN 1725, EN 747 and EN 716 for beds and children’s products.
- Checks address worktop height, reach, passage and opening clearance, kitchen work triangle, seat-to-table fit, school size classes, knee clearance and turning space.
- Ergonomic rule scope includes EN 1729, EN 527, TS 9111 and ISO 21542 sources, with the selected edition and project conditions recorded.
Default workflow
Select the product family and use setting, then review the standard checks.
Expert controls
Adjust load cases, safety factors, anthropometric tables and project requirements.
Correctness checks
Beam and moment calculations are compared with closed-form solutions; ergonomic limits with source tables. Material sheets and laboratory reports provide comparison evidence for the prechecks.
Paint, lacquer and surface finishing
Calculate coated areas from the model and connect coating, mixing and drying rules to consumption, time and line sequencing.
- Input
- Part faces and edges, machining geometry, coating system, colour, transfer efficiency and line capacity.
- Output
- Material and time per coat, finishing-line sequence, hanger and trolley layouts, solvent and volatile organic compound calculations.
Rules and parameters
- Primer, filler, topcoat and intermediate sanding stages carry consumption, mixing ratio and pot-life data.
- Visually matched RAL or NCS surfaces remain in the same batch; colour-change sequencing, drying time and rack capacity are planned together.
- UV, curtain and roller line settings and spray-booth limits feed costing and scheduling.
Default workflow
Select a coating system; consumption and time feed product cost.
Expert controls
Adjust transfer efficiency, line parameters and colour-sequencing rules.
Correctness checks
Surface area is checked against closed-form calculations; consumption against coating manufacturer sheets and recorded usage.
Pressing, veneers and door production
Plan membrane pressing, veneering and lamination from table loading to foil and adhesive consumption.
- Input
- Door geometry, press table, supports, foil dimensions, veneer leaves, colour and layer structure.
- Output
- Press-table layout, foil usage and waste, veneer cutting and jointing plan, press cycle, profile and glass cutting lists.
Rules and parameters
- Part spacing, support height, foil width and length and colour-batch rules constrain table loading.
- Veneer leaves are cut and joined according to the matching pattern; lamination follows balancing-sheet rules for the two faces.
- Framed, profiled, glazed, lacquered and membrane doors connect profiles, glass, carcass and finishing operations within the same model.
Default workflow
Select doors and the press profile, then generate the table plan.
Expert controls
Adjust spacing, press cycles, veneer matching and bonding parameters.
Correctness checks
The layout validator checks collisions, spacing and table boundaries; foil consumption is compared with production records.
Solid wood and joinery
Bring timber defects, moisture movement and rough-size allowances into cutting and joint decisions.
- Input
- Species, moisture, grade, thickness, width and length; defect areas, part-quality requirements and joint rules.
- Output
- Ripping and crosscutting plans and yield, rough and finished sizes, laminated-panel plans, joint machining and bending-form developments.
Rules and parameters
- Choose crosscut-first or rip-first processing; scanned or manually marked defects are checked against part-quality needs.
- Calculations cover planing and sanding allowances, lamella width and growth-ring direction, species- and moisture-dependent tangential and radial movement, and tabletop fixing allowance.
- Mortise-and-tenon, dovetail, finger, interlocking, dowel and biscuit joint rules accompany turned, curved and laminated-bending geometry.
Default workflow
Select species and grade to obtain the cutting list and yield.
Expert controls
Adjust grading rules, movement coefficients and joint dimensions.
Correctness checks
Wood movement calculations use published wood-technology tables; sawing plans are assessed with an independent validator and 1D/2D benchmarks.
Upholstery, foam and sewing engineering
Calculate frames, foam, springs and covers in one product structure, grading pattern sets by rule as dimensions change.
- Input
- Product model, plywood and solid-wood frames, foam blocks, density and firmness, pattern sets and sewing operations.
- Output
- Frame and foam cutting plans, contour-cutting files, spring, webbing and fibre lists, thread and piping lengths, and operation times.
Rules and parameters
- Plywood frames use free-form nesting, solid-wood frames use timber rules and foam blocks use three-dimensional cutting.
- Foam bonding layers, stitch length, zips and piping, size grading and matched pattern pieces are tracked together.
Default workflow
Select the product model and generate its material list and linked cutting plans.
Expert controls
Adjust pattern-grading rules, foam-cutting priorities and operation-time tables.
Correctness checks
Verification uses a three-dimensional cutting validator and published packing examples; consumption is compared with production sheets.
Metal frames, tubes and profiles
Prepare furniture metalwork with its cutting, bending, welding and wood-connection details.
- Input
- Profile catalogue, tube and sheet geometry, bend tables, K-factor and welding rules.
- Output
- Tube and profile cut lists, sheet developments and laser DXF, bend sequence, weld list, powder-coating area and hanger plan.
Rules and parameters
- Mitre and compound angles, end machining, bend allowance, minimum radius and springback are assessed together.
- Sheet nesting uses free-form layouts; weld length and fixture references link to the assembly. Wood and metal connection holes share the model.
Default workflow
Select a profile and generate cut lists and flat patterns.
Expert controls
Adjust bend tables, K-factors, welding rules and bend order.
Correctness checks
Developed lengths are checked against closed-form solutions and manufacturer tables; bend collisions use a geometry validator, with linear cutting benchmarks for stock use.
Glass, mirrors and worktop preparation
Prepare glass and worktop orders with dimensioned geometry, edge profiles and cut-out information.
- Input
- Glass type and thickness, hinge and holder patterns; laminate, compact, stone or acrylic worktop models.
- Output
- Glass cutting and supplier sheets, dimensioned drawings, weight and support calculations; worktop joints, sink and hob cut-outs, front edges and upstands.
Rules and parameters
- Define float, toughened, laminated, mirrored and frosted glass with ground or bevelled edges, holes and notches. Sources within EN 12150 scope inform hole and edge-distance rules.
- Guillotine glass layouts retain breaking allowances; hardware holes derive from catalogues and weight is checked against support limits.
- Furniture prepares worktop ordering geometry and its slab-layout relationship. Bridge-saw and waterjet stone manufacturing belongs to the separate Stone product.
Default workflow
Select the glass or worktop material and generate an order sheet.
Expert controls
Adjust glass rule sets, cutting layouts, worktop joints and edge profiles.
Correctness checks
Glass values are assessed against standards and manufacturer sheets using boundary cases; drawing and order dimensions are compared with the source model.
Furniture lighting and electrics
Plan LED strips, drivers, cables and socket modules alongside the part list and machining geometry.
- Input
- Strip and driver catalogues, total load, reserve margin, cable cross-section, routes, sensor and switch selections.
- Output
- LED, profile and diffuser cut lists, driver selection, voltage-drop calculations, wiring diagrams and installer sheets.
Rules and parameters
- LED cutting increments, driver ventilation, safety extra-low-voltage separation and cable openings are checked together.
- Sensor, switch, recessed socket and charging-module placement connects to grooves and cable holes in the production model.
Default workflow
Choose a preset such as under-shelf lighting.
Expert controls
Adjust driver and strip data, voltage-drop limits and diagram rules.
Correctness checks
Power and voltage drop are compared with closed-form calculations, and driver selection with manufacturer sheets.
Discuss your production workflow
Tell us about your cutting lists, materials and machines. We will prepare the discussion around the inputs you use and the outputs you need.