Sales teams, dealer managers, contract furniture manufacturers and product pricing teams.
Sales
Base each quotation on the product you will manufacture. Cutting results, materials, machine time, labour and packaging feed one cost breakdown, with the same product rules carried from sales to production.
Materials, time and product cost
Separate board consumption with and without waste, then include edging, hardware, glue, fabric, leather, glass and worktops. Production quantities such as cutting length and hole count drive the time calculation.
- Input
- Bill of materials, nesting result, material prices, machine profiles, operation times and overhead rates.
- Output
- Material, machine, labour, assembly, packaging and logistics cost lines by product and order, with estimated versus actual comparisons.
Rules and parameters
- Machine time separates cutting, drilling, tool changes, loading, unloading and setup. Recorded measurements calibrate each time model.
- Machine rates, station labour, allocated overheads, transport and on-site assembly remain separate. Load plans can supply freight allocation per product.
- Currencies, exchange tables, VAT, decimal precision and amount rounding use the organisation settings.
Default workflow
Enter material prices and one margin rule, using the initial machine and time profiles.
Expert controls
Edit time formulas, overhead allocation, machine and labour rates, exchange tables and rounding rules.
Correctness checks
Verification uses hand-calculated cost tables, total consistency, tax and rounding boundary cases, and comparisons with manufacturer cost sheets.
Alternative quotations and order handover
Compare material and hardware options with the customer. Keep validity, payment and delivery terms, revisions and approval status connected to the product manufacturing data.
- Input
- Customer record, products and quantities, cost result, price list, and customer or dealer discount rules.
- Output
- Itemised quotations with alternatives, bilingual documents, revision history and order data from an accepted quotation.
Rules and parameters
- Margin, campaigns and quantity breaks are evaluated by the pricing engine; each quotation option retains its product revision.
- Turkish number, date and document conventions and company letterheads are supported. Accounting, collections and sales pipeline management connect through the ERP.
Default workflow
Choose a product and quantity, create a quotation with preset terms and convert it to an order when accepted.
Expert controls
Manage customer and dealer prices, option packages, discounts, quantity rules and document templates.
Correctness checks
Quotation totals are recalculated from source costs and pricing rules, with separate checks for currency, tax, rounding and revision consistency.
Price engineering and catalogue scenarios
See which products are affected when boards, hardware, exchange rates or labour costs change. Link target costs to design suggestions and generate price lists from size and option matrices.
- Input
- Product catalogue, current costs, scenario inputs, target prices and margin rules.
- Output
- Batch recosting, affected products, margin changes, target cost gaps, price matrices and campaign impact.
Rules and parameters
- Standard versus actual cost variances are separated by line; scenarios can be compared before changing the price list.
- The change needed to reach a target cost is broken down into materials, machining and other costs; design changes retain their locks and bounds.
Default workflow
Change one cost input and inspect the affected products.
Expert controls
Define multivariable scenarios, price steps, rounding and option matrix rules.
Correctness checks
A scenario result is checked against a fresh run of the cost engine using the changed inputs.
3D product configuration on your website
Customers choose dimensions, materials, colours, fronts, handles and interior fittings within the production model limits. The same cost engine calculates prices and accepted selections become manufacturing models.
- Input
- Published product template, option and pricing rules, materials and channel settings.
- Output
- Real-time 3D product, price, quotation request or order, followed by a model connected to cutting lists and work orders after approval.
Rules and parameters
- Embed the configurator under your domain and brand. It reads only a published copy of a frozen revision; customers cannot view draft products.
- Invalid combinations cannot be selected. Visual options include physically based materials, textures, environment lighting, high-resolution images and phone-based room placement.
- Publication management defines cart, quotation request and direct order flows, dealer prices, and visit and conversion reporting.
Default workflow
Choose a product template and publish its permitted options.
Expert controls
Configure option dependencies, pricing rules, embedding settings and dealer channels.
Correctness checks
Verification covers agreement with the internal pricing engine, manufacturability of selectable combinations, browser compatibility and load behaviour.
Rendering studio for catalogues and sales
Turn the production model into catalogue imagery with scene, lighting and material controls. Render colour and size variants in batches from a consistent camera angle.
- Input
- Product scene, décor textures, material properties, cameras, lighting and sampling settings.
- Output
- Photorealistic images, 360-degree product views, panoramas, camera-path video, browser-based virtual-reality tours and e-commerce 3D asset packages.
Rules and parameters
- Server-side physically based ray tracing uses fixed sampling and seeds. Scene templates, camera presets and lighting sets can be reused.
- Décor manufacturer textures connect to the material library, with measured reference values used for colour management.
Default workflow
Choose a preset scene and generate the product image set.
Expert controls
Edit lighting, cameras and materials, and define batch jobs for variants.
Correctness checks
Checks compare repeated renders from the same scene and seed, and décor colours against measured references.
One catalogue for dealers and sales channels
Publish product codes, variants, price matrices and imagery from one catalogue. Catalogue revisions and price changes carry through to the target format.
- Input
- Products for publication, dimension and option tables, prices, images and channel field mappings.
- Output
- IDM, OFML and BMEcat catalogue data, ECLASS classifications, and marketplace and search-engine product feeds.
Rules and parameters
- Map IDM fields for kitchens, bathrooms and seating, and OFML fields for office furniture. Feeds include titles, attributes, images, stock and prices.
- Variant expansion and product code rules are tracked through catalogue version comparisons and price change lists.
Default workflow
Select the products and target catalogue format.
Expert controls
Manage field mappings, product code rules and channel-specific pricing.
Correctness checks
Outputs are checked using the format’s official schema and validation tools; catalogue prices are recalculated by the shared pricing engine.
Room schedules for contract furniture projects
Manage contract furniture from room types and quantities through product allocation, sample approval and room-specific carton labels.
- Input
- IFC or DWG room data, Excel quantity schedules, FF&E items, specifications, products and quantities.
- Output
- Room-based product schedules, specification and sample approvals, mock-up rooms, floor and room batches, packaging labels and progress data.
Rules and parameters
- Cartons retain block, floor and room references. Production, delivery and installation progress is associated with rooms and items, while snag lists link to the affected product.
- Furniture manages project and design data. Progress billing, deductions, advance offsets and variation charges belong to XRP; approved changes return as items or quantities.
Default workflow
Import the room schedule and assign products to each room type.
Expert controls
Manage item mappings, sample and design approvals, revisions and room-based batch rules.
Correctness checks
Production quantities are recalculated from room types and counts; checks ensure batches, cartons and labels retain their room references.
Controlled product publication for dealers and customers
Dealers see their catalogue, prices and orders. Customers review approval drawings through signed, time-limited links, submit approval or revision requests, and follow order status.
- Input
- Frozen product revision, channel publication, dealer catalogue and prices, and customer approval documents.
- Output
- Dealer orders, recorded customer approvals or revision requests, and part selections and spare-part requests from the product QR page.
Rules and parameters
- A dealer is a separate organisation and reads only its published copy. External surfaces have separate sessions and cannot view drafts.
- The product QR page links to the manufactured revision, passport, manual and exploded view. XRP manages service and warranty; an ordered spare part returns to production with its original model and program.
Default workflow
Publish an approved product or drawing to the appropriate dealer or customer channel.
Expert controls
Manage channel scope, dealer prices, publication revisions and link access.
Correctness checks
Checks separately verify the publication copy, access scope and source revision; the spare-part model hash is compared with the original part.
Discuss your production workflow
Tell us about your cutting lists, materials and machines. We will prepare the discussion around the inputs you use and the outputs you need.