CNC manufacturers, planners, workshop supervisors, series-production and loading teams.
Production
Keep the same part identity from approved production model to machine file, workstation and carton loading. Planners see capacity, operators see the next job, and engineers see the revision behind each program.
CNC toolpaths and cutting strategies
Turn layouts and machining features into toolpaths, programs, time estimates and preparation information.
- Input
- Validated layouts, machining features, machine definitions and material-specific tool and cutting data.
- Output
- Contour, pocketing, drilling, grooving and engraving paths; programs, tool lists, time estimates and simulation reports.
Rules and parameters
- Tool diameter, length, flute count, feed, speed, plunge, pass depth, magazine positions and multi-spindle drilling layout belong to the machine profile.
- Define leads, ramps, climb or conventional cutting, onion skin and finishing passes, tabs and small-part strategies.
- Common edges, vacuum zones, part order, rapid travel and tool changes are evaluated together.
- Toolpath animation, material removal, tool and holder collisions, suction cups and working-envelope limits are examined with the program.
Default workflow
Select the machine and a standard tool set, then generate programs.
Expert controls
Adjust cutting data, strategies, small-part rules and operation order.
Correctness checks
Geometry reconstructed from toolpaths is compared with model features; the time model retains the data needed for comparison with actual machine measurements.
Post-processors and multi-face drilling
Generate machine-specific programs with tool and workholding definitions, checking file format and actual machine acceptance separately.
- Input
- Part features, machine post-processor, suction-cup and clamp positions, turnover steps and tool set.
- Output
- Part-based or nesting programs, multi-face drilling sequences, board-loading sheets and program-to-label links.
Rules and parameters
- Post-processor scope covers Homag/Weeke woodWOP MPR, Biesse CIX, SCM Maestro/Xilog, Holz-Her NC-Hops HOP, Felder/Format-4 and generic ISO G-code.
- Machine definitions are data-driven; a post-processor name alone is not acceptance evidence for a specific machine model or installation.
- On point-to-point machines, datum faces, cups, clamps and turnover order determine feature access; preparation sheets match the programs.
Default workflow
Select a defined machine profile and generate its program set.
Expert controls
Adjust post-processor definitions, face mapping, workholding and operation order.
Correctness checks
Verification covers official format documentation, opening in the machine manufacturer’s software, geometry read-back and physical machine trials. Machine-specific acceptance depends on those records.
Panel-saw output and stack cutting
Convert cutting patterns into files using the saw’s sequence, clamping and stack rules.
- Input
- Layout plan, board thickness, saw projection, machine limits and stack strategy.
- Output
- Machine files, operator sheets, cutting and part-outfeed order, stacking plans and part/offcut label flow.
Rules and parameters
- Format scope includes Homag/Holzma PTX and official import formats, Biesse/Selco, SCM/Gabbiani and generic CSV/XML patterns.
- Stack height is limited by saw projection and board thickness; repeated patterns are considered to increase stack-cutting opportunities.
- Rules cover head cuts, edge trims, recuts, stress-relief cuts, strip rotation, minimum clamping allowance and maximum cut length.
Default workflow
Select the saw and download the file or send it to the configured network folder.
Expert controls
Adjust machine limits, stack rules, cut order and outfeed stacking strategy.
Correctness checks
The plan read back from the file is compared with the source. Official format checks, manufacturer software and physical trials are machine-specific verification steps.
Batches, work orders and finite capacity
Connect orders to production routes and build batches and schedules using combined cutting, setup and due-date effects.
- Input
- Orders, materials and colours, due dates, operation routes, machine capacity, shifts and calendars.
- Output
- Work orders, batch plans, machine and workstation assignments, schedules, bottleneck views and order cost allocation.
Rules and parameters
- Routes include sawing, edgebanding, drilling, CNC, assembly and packing. Jobs grouped by material, colour, due date and machine are compared with separate cutting.
- Finite capacity, priority, shifts and calendars remain enforced; stock reservations and board, edging, hardware and offcut movements link to the job.
- Minimum-stock alerts and counts belong to basic stock scope. With XRP connected, XRP owns stock levels and locations while Furniture publishes production consumption and offcut receipts.
- An outsourced operation can be marked and packaged with drawings, lists, labels and machine outputs; subcontract orders and commercial reconciliation are handled by ERP.
Default workflow
Select the order and create its batch and work order using the standard route.
Expert controls
Adjust route templates, capacity, scheduling rules and cost allocation.
Correctness checks
State transitions, stock-movement invariants and schedule validity are checked separately; published shop-scheduling examples and factory workflows provide comparison methods.
Shop-floor stations, barcodes and traceability
Show operators the next job, part drawing and program, and link each scan to the operator, workstation and revision.
- Input
- Station key, operator badge or PIN, part and carton labels, job queue and machine authorisation.
- Output
- Start/finish records, part traceability, issues and remanufacturing requests, offcut receipts, carton-completion and loading records.
Rules and parameters
- The operator surface exposes next-job, part, issue, offcut, carton and loading steps; it does not modify the production model.
- Only operation status, issues and stock movements can be written. Offline scans queue for ordered replay with idempotency keys.
- A part retains its source board, machine, operator and time. Basic inspection points, nonconformances and scrap reasons link to production records.
- Carton completion exposes missing parts. Full quality management, maintenance, personnel competence and service processes are handled through ERP integration.
Default workflow
Scan your badge and the part label, then start or complete the next operation.
Expert controls
Define workstation queues, authorisations, inspection points and remanufacturing routing.
Correctness checks
Checks cover the state machine, single effect of repeated scans, offline ordering, stock consistency and the identity chain from board to carton.
Factory layout and material flow
Place machines with their operating, service and feed areas, then compare material travel distances across alternative layouts.
- Input
- DXF or DWG building plans; machine sheets, route intensity, buffers and service connections.
- Output
- Machine layout, flow diagrams, travel distance and intensity, aisle checks, extraction routes and total airflow demand.
Rules and parameters
- Machine records retain footprint, service and operator zones, board-feed direction and electrical, compressed-air and extraction connections.
- Buffers, aisles and escape-route widths are checked against selected project rules; weighted routes support layout comparisons.
- Extraction demand is calculated from the model and can be exported to business systems; occupational-safety record management belongs to ERP scope.
Default workflow
Place machines on the plan and review collision and flow indicators.
Expert controls
Adjust route weights, layout optimisation and service layers.
Correctness checks
Areas and distances are compared with hand-worked examples, machine dimensions with source sheets and layouts with published facility-layout benchmarks.
Container, truck and pallet layouts
Place cartons and assembled products using actual equipment dimensions, weight limits and delivery order, with separate volume and weight utilisation.
- Input
- Carton dimensions, mass and centre of gravity, permitted orientations and stacking loads; assembled products and nesting increments; order, stop and equipment data.
- Output
- 3D load plans, mixed pallets, equipment count and utilisation, centres of gravity and axle loads, proven lower bounds and gaps.
Rules and parameters
- The library covers 20/40/40 HC/45 HC containers, reefers, open tops and flat racks; trailers, trucks and vans; EUR/EPAL, ISO and custom pallets, with sourced internal dimensions, doors, tare, capacity and securing points.
- Palletised, floor-loaded and mixed loads retain indivisible orders and customer, block, floor and room groups. Upright glass, protected faces and stacking-chair increments are enforced.
- Rules enforce full bottom support by default, centre of gravity within the support area, stability at each step, top loads, layer limits, heavy-below/fragile-above placement and load-bearing faces.
- Checks cover doorway passage and position access, floor and pallet loads, kingpin and axle-group limits. Reefer airflow, van wheel arches, open-equipment overhangs and securing are separate constraints.
- Last-off loads go in first, with side-curtain access also modelled. Access, remaining-load balance and axle loads are reassessed after every stop.
- Objectives prioritise equipment count or cost, then utilisation, balance and loading ease. Fleet quantities, stacked pallets, overhang, dunnage and maximum free-gap limits remain enforced.
- Volume, weight and packing bounds establish the lower bound. Optimality is stated only at zero gap; manual moves and rotations are validated live.
Default workflow
Select orders and equipment type, then generate a plan using the packaging rules attached to each carton.
Expert controls
Adjust support ratios, grouping, stacking, objectives, fleet and freight inputs, axle and centre-of-gravity windows and plan locks.
Correctness checks
Independent checks cover fit, overlap, doorway access, support, weight, axles, stop access and quantities. Verification uses BR1-BR15 and 3D packing benchmarks, hand calculations and determinism checks.
Loading sheets, securing prechecks and design feedback
Turn the plan into an executable loading sequence and feed carton-size effects on units per container back into costing and design.
- Input
- Validated load plan, friction and acceleration coefficients, equipment limits, carton-size locks and freight inputs.
- Output
- Stepwise loading and unloading sheets, staging lists, pallet labels, missing-carton lists, securing and dunnage notes, and freight allocation per product.
Rules and parameters
- The 3D view filters by stop and order with sections and step playback. Carton scanning shows the next position and flags an incorrect sequence or equipment.
- Top-over and direct-lashing counts, blocking and chocking needs are presented as preliminary calculations. EN 12195-1 and CTU Code sources are considered within the project rule scope.
- Size suggestions derived from equipment-to-carton fit thresholds are validated with the full solver. Carton changes propagate to part dimensions within locks and limits; acceptance creates a new revision.
- Units per container feed the catalogue, costing and quotations; freight per product becomes a logistics cost line. Volume, net mass and gross mass are reported separately.
- Load plans, summaries, finalisation and scan-completion data pass to ERP; route order and assigned equipment return. Route/vehicle assignment, appointments, carrier contracts, customs and delivery receipts belong to ERP.
- A fit query accepts the route and vehicle proposed by the ERP and returns whether the cartons fit, together with utilisation.
Default workflow
Follow the loading sheet and confirm positions by scanning carton labels.
Expert controls
Adjust securing inputs, allowed gaps, carton-size limits and logistics cost allocation.
Correctness checks
Securing and axle calculations are assessed against hand-worked examples; suggestions are re-solved. Equipment, weight and securing rules are matched to relevant official sources and equipment sheets before use.
Discuss your production workflow
Tell us about your cutting lists, materials and machines. We will prepare the discussion around the inputs you use and the outputs you need.