Manufacturers with existing design or ERP systems, production engineers and organisation administrators.

Integration and platform

Bring existing design data into production while keeping your design workflow. File import, ERP connections and user access work around one manufacturing model, revision history and verification rules.

CSV, Excel and existing cutting lists

Import part lists without re-entering them. Start from preset cutting-list profiles and save column mappings for your organisation.

Input
CSV and Excel with part data, finished and cutting dimensions, four edge-band codes, grain, quantity, material, order, locks and bounds.
Output
Validated manufacturing model, import report with row and column locations, source-linked parts and reusable mapping profile.

Rules and parameters

  • Units come from the file; missing units require a user selection and are never guessed. Millimetres, centimetres, metres, inches, decimal commas and points are supported.
  • Errors, warnings and information include a code, source location and Turkish or English message. Cutting lists and product-library files from existing tools use mapping profiles.
  • Part, stock, price and customer lists can be exported, edited and imported again.

Default workflow

Upload the file, confirm mappings and correct the error list in the table.

Expert controls

Define mapping profiles, material tables, batch jobs and API imports.

Correctness checks

Verification uses reference files for each error code, model equality after file round trips, and comparisons between formats representing the same product.

Recognising DXF, DWG and PDF drawings

Read drawings through layer, block and attribute rules. Geometry recognition, view matching and dimension checks create parts with traceable links to the source drawing.

Input
Layered DXF, DWG, vector and scanned PDFs, with layer rules, scale and recognition tolerances.
Output
Part candidates, holes and pockets, edging and groove marks, matched views and relationship suggestions requiring approval.

Rules and parameters

  • Closed outer contours become part candidates, inner contours become holes or pockets, and circles become hole candidates. Front, top and side views match by alignment and dimensions; dimension text is compared with geometry.
  • Vector PDFs provide paths, text and scale. Scanned pages use conventional contour tracing and dimension-text reading, with every extracted value requiring user confirmation.
  • Equal dimensions, shared edges, symmetry and thickness-based relationships are suggested but never confirmed without approval. Problem geometry is highlighted in 2D and 3D.

Default workflow

Upload a file, confirm recognised parts and dimensions, and resolve highlighted discrepancies.

Expert controls

Edit layer and block rules, recognition tolerances, view mappings and material tables.

Correctness checks

Checks retain source-layer and geometry references, compare models from different formats, and read exported drawings back.

STEP, IGES and portable project models

Read 3D assemblies body by body to identify panels, holes, grooves and joint relationships. Native project packages carry models, revisions and library references together.

Input
STEP AP203, AP214 and AP242, IGES, or a versioned and signed native project package.
Output
Material-mapped parts, hole and groove features, joint suggestions, consolidated identical bodies and reports with source identities.

Rules and parameters

  • Two large parallel faces and constant thickness identify a panel. Thickness, colour and layer names map to materials; identical bodies consolidate into a part and quantity.
  • Cylindrical faces provide hole diameter, depth and direction; pockets yield grooves and rebates. Face contact and aligned axes inform joint suggestions.
  • One manufacturing model contains products, modules, parts, features, materials, hardware and operations. Packages transfer between installations with revision and library links.

Default workflow

Upload the assembly and confirm proposed material and part mappings.

Expert controls

Edit geometry tolerances, material mappings and batch import profiles.

Correctness checks

Verification examines source-body traceability, reference assemblies and model equality across formats; recognition results on manufacturer drawings are reported separately.

Public APIs, signed events and file connections

Connect models, jobs and results through a public REST API. Transfer machine files through network folders and deliver events to other systems through signed webhooks.

Input
API key and scope, REST requests, webhook destination, model identities and machine file location.
Output
Model and result data, job status, signed events, file transfers and received machine feedback.

Rules and parameters

  • OpenAPI documentation, key scopes and rate limits govern access. Event envelopes carry identity, type, time, organisation, subject, revision and content hash.
  • Webhooks use at-least-once delivery; recipients deduplicate by event identity and order is preserved per subject. REST writes carry idempotency keys.
  • Network folders and file drops are Furniture capabilities. Live machine monitoring, OEE and maintenance are ERP responsibilities; received actual time, tool-life and energy data feed the relevant calculations.

Default workflow

Start with a scoped key and a predefined file-transfer path.

Expert controls

Configure scopes, event mappings, redelivery handling and machine file workflows.

Correctness checks

Verification uses contract fixtures for every endpoint and event, signature and replay checks, and file round trips compared with the source model.

SoSo Enterprise XRP and other ERP connections

Exchange BOMs, recipes, work orders, stock movements, purchasing requirements and costs with the ERP. SoSo Enterprise XRP and other ERP mappings use the same public contract.

Input
Customer, dealer, order, price, exchange-rate, tax, stock, shift and competence data, plus ERP identity mappings.
Output
Product and operation data, quotations, costs, work packages, packing units and load summaries, plus UBL-TR e-invoice and e-archive content and accounting entries.

Rules and parameters

  • Furniture owns product, part, feature, plan, output and calculation records. External identities stay in mapping tables; amounts use minor currency units and dimensions use integer units.
  • The ERP manages customers, suppliers, contracts, invoices, progress billing, collections, dealer commercial management, shifts and competence. Without an ERP, Furniture retains basic quotations, stock, work orders and quality records.
  • Furniture produces subcontract work packages and receives order and receipt status from the ERP. Routes and vehicle assignments come from the ERP; Furniture calculates geometric load plans. Export and customs documents are prepared by the ERP.
  • Advanced quality, calibration, maintenance, workplace safety records, training, warranty and service belong to the ERP. Furniture shares inspection, nonconformance, consumption, waste and validation data, and links returned measurements and spare-part orders to the model.

Default workflow

Select an ERP mapping and align product, order and price flows with company records.

Expert controls

Manage record ownership, external identities, event mappings and UBL-TR document fields.

Correctness checks

Both systems use identical contract fixtures; identity and idempotency are checked. UBL-TR output passes through schema and Schematron validation.

Architectural BIM and 3D asset exchange

Deliver furniture to the architect’s model with type, instance and property data. Import rooms, walls and levels to review clashes between furniture, building elements and services.

Input
Product or project model, architectural IFC, and property and classification mappings.
Output
IfcFurniture and IfcSystemFurnitureElement objects, BIM catalogue packages, 2D and 3D DWG blocks, glTF, FBX, OBJ and USDZ.

Rules and parameters

  • Types and instances remain distinct, with property sets, classification codes and COBie asset fields mapped explicitly.
  • Choose envelope, medium or full detail according to the use case. Imported rooms and levels connect to project product assignments.

Default workflow

Choose a product or project and export the IFC package.

Expert controls

Edit property sets, classifications and detail-level rules.

Correctness checks

Verification methods include the official IFC schema, model equality after round trips and inspection in independent IFC viewers.

Workspaces, roles and shared libraries

A small workshop can work in the quick-cut screen while designers, engineers, planners, sales and compliance teams use their own workspaces. Switching areas preserves the project, revision and selected part.

Input
Membership, permission role, workspace access, licensed modules and shared catalogue records.
Output
Design, Engineering, Production, Sales, Compliance, Library and Administration workspaces, with access-filtered menus, search and related-record links.

Rules and parameters

  • Owner, admin, editor, reviewer and viewer roles intersect with none, read or write access per workspace. Job profiles provide preset combinations.
  • Tenant RLS, server-side permission and licence checks, central Keycloak OIDC and write audit records govern access. Operators use a separate station to record status, issues and stock movements without editing the model.
  • The library shares materials, boards, edging, hardware, machines, tools and published construction standards, with starter data, bulk import, record history and usage references.
  • Unlicensed module screens are hidden while their data is preserved. Full validation still runs; invalid affected data prevents revision freezing and is never silently removed.

Default workflow

Choose a job profile and the required modules, then use built-in help, example projects and starter libraries.

Expert controls

Manage workspace access, catalogue ownership, module dependencies, and company language, units, templates and numbering.

Correctness checks

Role and tenant isolation, licence gates and module dependencies are checked separately; search and links use the same permission scope.

Revisions, approvals and product-range analysis

Track product codes, variants and lifecycle through revisions. Change orders, comments and approvals stay linked to the product, while manufacturing data reveals common parts and waste across the range.

Input
Product catalogue, revisions, changes, operation and cutting results, suggestion decisions and actual records.
Output
Revision comparisons, approvals and activity feeds, plus common-part ratios, part variety, setup counts, waste breakdowns and suggestion outcomes.

Rules and parameters

  • Concurrent work uses record locks and conflict resolution. Each result stores input hashes and rule and solver versions; identical inputs produce identical results.
  • Product-range analysis links material and machine losses, waste-producing products and parts, suggestion acceptance and actual savings to source records. Delivery, machine-load, sales and profitability business dashboards remain in XRP.
  • Excel, CSV and Parquet exports and read-only data connections serve business-intelligence tools. Measured results remain separate from assumptions.

Default workflow

Use preset revision comparisons and product-range dashboards.

Expert controls

Configure approval flows, analysis metrics and read-only data access.

Correctness checks

Every metric is recalculated from source records; checks cover reproducibility with identical inputs and versions, revision immutability and access scope.

SaaS, on-premises deployment and data portability

Use the same production and calculation model in SaaS or on premises. Offline installation, backup, restore and exit packages form part of company data management.

Input
Deployment choice, organisation data, module and limit scope, backup and export settings.
Output
SaaS or on-premises installation, versioned project transfer, backup and restore workflows, data exports and exit packages.

Rules and parameters

  • Furniture operates with its own product identity, licence and data domain. Module and limit scopes cover seats, optimisation jobs, machines, stations, published products, sessions, API use and storage.
  • The solver runs on the server with fixed seeds and deterministic limits, treating identical inputs consistently in SaaS and on-premises installations. Every plan reports a proven lower bound and its gap.
  • Independent validators, libraries and the model form the core; modules communicate through models and outputs. Optimality is claimed only when the gap to the lower bound is zero.

Default workflow

Choose the deployment and modules your work requires, then start with the initial libraries.

Expert controls

Configure backups, exit packages, organisation access, resource limits and module scope to match company policies.

Correctness checks

Licence and control contracts use fixed examples, with separate role and RLS checks. Backup restoration and deployment acceptance require verification in the chosen environment.