StandardCitation2017

Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock

IEC · IEC TC 64

The core low-voltage safety part that sets essential requirements for protection against electric shock of persons and livestock and the conditions for additional protection such as RCDs.

On this page

Overview

IEC 60364-4-41 is the core safety part of the low-voltage electrical installations series, dealing with protection against electric shock. It specifies essential requirements for protecting persons and livestock. The version described here is the consolidated text merging the 2005 fifth edition and Amendment 1 (2017), and it includes the February 2018 corrigendum. This page rests on the publisher's public catalogue abstract.

The standard deals with the application of these requirements and their coordination in relation to external influences. In other words, the choice of protective measure does not stand apart from the conditions of the environment where the installation sits. It also gives requirements for additional protection in certain cases, with residual current devices (RCDs) as the typical example.

The consolidated text runs to 152 pages, and a new edition is in preparation per its lifecycle. Related documents include IEC 60364-4-43, IEC 60364-5-54 and HD 60364-4-41, covering overcurrent protection, earthing arrangements and the European harmonised text respectively.

Consult the standard itself for those values.

Key points

  1. Specifies essential requirements for protection against electric shock of persons and livestock.
  2. Deals with application and coordination of the requirements in relation to external influences.
  3. Gives requirements for additional protection in certain cases.
  4. Consolidated version: edition 5 (2005) plus Amendment 1 (2017), with the February 2018 corrigendum included.
  5. 152 pages; a new edition is in preparation.
  6. Related documents: IEC 60364-4-43, IEC 60364-5-54, HD 60364-4-41.
  7. The standard is paid; the full text is not redistributed.

Using it in design

  • In a fault-loop checker, compute fault-loop impedance for each final and distribution circuit and verify automatic disconnection times for the chosen earthing system.
  • Flag circuits that need additional RCD protection.
  • Treat this as a hard check that must pass before cable sizing is accepted.

Monthly newsletter · free

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.

SoSo CAD

Review your power design in SoSo CAD

Inspect supply paths, equipment loads and UPS failure scenarios in one model.

Request a demo
Single-line diagram in the SoSo CAD power and capacity workspace

Who should read it

Electrical engineers designing low-voltage distribution for data centres, and electrical safety reviewers.

Related standards

  • IEC 60364-4-43
  • IEC 60364-5-54
  • HD 60364-4-41

Publication details

Authors
IEC TC 64
Publisher
IEC
Year
2017
Document number
IEC 60364-4-41:2005+AMD1:2017
Document language
English
Source type
Standard
Access
Citation only
Licence
Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note

Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.

Citation

IEC TC 64 (2017). Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock. IEC. IEC 60364-4-41:2005+AMD1:2017. https://webstore.iec.ch/en/publication/60169

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.