TSE adoption lookup for EN 50600-2-1 (unverified)
Türk Standardları Enstitüsü (TSE)
EN 50600-2-1 is the building and construction part of the EN 50600 series. This page summarises the record on whether TSE has issued a stand-alone TS name for that part.
On this page
Overview
Its place in the series: -2-1 deals with the data-centre building and construction, while power distribution, environmental control and cabling are left to their own parts. The records in hand do not relay any requirement from inside this part.
Nor would it be right to say anything about an availability class for the building: in the records, the EN 50600-1 classes are listed for power, environmental control and cabling, and the building is not on that list. Building decisions should therefore be tied to the standard's own text rather than to a class label.
TSE's January-February 2024 bulletin names the -2-x parts collectively, and no separate TS designation for -2-1 has been verified. Whether TS EN 50600-2-1 exists as a Turkish-language edition, and in which year or language it appeared, is not known. As the European counterpart, the 2024 CEN-CENELEC brochure shows EN 50600-2-1:2021, which does not confirm today's status.
Key points
- Scope: the data-centre building and construction infrastructure (EN 50600-2-1).
- The records relay no numeric or class-based requirement for the building.
- EN 50600-1 classes are listed for power, environmental control and cabling; the building is not among them.
- The TSE bulletin names the -2-x parts together; no individual TS designation for -2-1 was found.
- The 2024 CEN-CENELEC brochure shows the European edition as EN 50600-2-1:2021.
Using it in design
- In early building and construction design, do not treat this record as a source of requirements; just note which part of the standard is relevant.
- For building criteria, obtain the text of EN 50600-2-1:2021 and justify building decisions by citing it.
- Read the parts side by side to confirm separately that the classes chosen for power, cooling and cabling do not conflict with the building.
Monthly newsletter · free
Keep your reading list current
Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.
SoSo CAD
Assess redundancy through scenarios
Compare normal operation and equipment failures in SoSo CAD, with supplied loads and capacity shortfalls in one view.
Request a demo
Who should read it
Architects, civil engineers and specification owners who map the data-centre building scope onto EN 50600.
Related standards
- EN 50600-2-1
Publication details
- Authors
- Türk Standardları Enstitüsü (TSE)
- Publisher
- Türk Standardları Enstitüsü (TSE)
- Year
- Year not stated
- Document language
- English
- Source type
- Standard
- Access
- Citation only
- Licence
- Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note
No permission to redistribute TSE standard texts is asserted. This record contains only bibliographic research metadata and official links; no standard text, excerpts or file.
Citation
Türk Standardları Enstitüsü (TSE) TSE adoption lookup for EN 50600-2-1 (unverified). Türk Standardları Enstitüsü (TSE). https://intweb.tse.org.tr/Standard/Standard/StandardAra.aspx
Events on this subject
Browse the events calendarAll content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.