StandardCitationYear not stated

TSE adoption lookup for EN 50600-2-2 (unverified)

Türk Standardları Enstitüsü (TSE)

EN 50600-2-2 is the power distribution part of the EN 50600 series. The record checks where the power distribution part stands in the TSE catalogue.

On this page

Overview

Part -2-2 handles the electrical side of the series: power supply and distribution. Because the EN 50600-1 availability classes apply to power as a separate selector, redundancy and concurrent-maintenance decisions are read together with this part.

The measurement levels in the series overview also land on the power path: level 1 covers the utility and UPS output, level 2 adds the PDU outputs, and level 3 means per-rack or IT-level metering. How these levels map onto -2-2 itself is not stated in the records.

Whether TSE has published 50600-2-2 as a Turkish-language TS edition is not confirmed. TSE has mentioned only the -2-x parts as a group, and no separate name, adoption year or Turkish title was found for this one. The European edition in the 2024 CEN-CENELEC brochure is EN 50600-2-2:2019.

Key points

  1. Scope: power supply and distribution (EN 50600-2-2).
  2. The EN 50600-1 availability classes apply to power as its own selector.
  3. Measurement levels in the overview: 1 = utility and UPS output, 2 = plus PDU outputs, 3 = per-rack or IT-level.
  4. TSE names the -2-x parts together; no separate TS designation for -2-2 was found.
  5. The 2024 CEN-CENELEC brochure gives the European edition as EN 50600-2-2:2019.

Using it in design

  • Keep the power distribution class selector independent of cabling and cooling, and document path count and redundancy against the class chosen.
  • On the single-line diagram, map metering points to levels 1-3 and record in the project notes which level is targeted.
  • In the power distribution rationale, cite the text of EN 50600-2-2:2019 and do not use the TS name alone as the source.

Monthly newsletter · free

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.

SoSo CAD

Assess redundancy through scenarios

Compare normal operation and equipment failures in SoSo CAD, with supplied loads and capacity shortfalls in one view.

Request a demo
Normal operation and failure scenario comparison in SoSo CAD

Who should read it

Design engineers building electrical distribution, UPS and metering architecture around EN 50600.

Related standards

  • EN 50600-2-2

Publication details

Authors
Türk Standardları Enstitüsü (TSE)
Publisher
Türk Standardları Enstitüsü (TSE)
Year
Year not stated
Document language
English
Source type
Standard
Access
Citation only
Licence
Copyright retained; citation only — the publisher’s terms apply to the original document
Original licence note

No permission to redistribute TSE standard texts is asserted. This record contains only bibliographic research metadata and official links; no standard text, excerpts or file.

Citation

Türk Standardları Enstitüsü (TSE) TSE adoption lookup for EN 50600-2-2 (unverified). Türk Standardları Enstitüsü (TSE). https://intweb.tse.org.tr/Standard/Standard/StandardAra.aspx