A five-page Turkish paper from the Akademik Bilişim 2013 conference (Akdeniz University, 23-25 January 2013) that introduces data centre design: energy, security, cooling, monitoring, raised floor and cabling.

On this page

Overview

The paper by Hüseyin Taner Gökmen and Ecir Uğur Küçüksille of Süleyman Demirel University appears on pages 93-97 of the XV. Akademik Bilişim Conference proceedings. It describes in general terms how a data centre should be, with the aim of protecting data and delivering it quickly. The text presents security, redundancy and continuity as the primary reason for a data centre and stresses the cost of changes made after installation.

The energy section notes that power demand in server rooms doubled between 2003 and 2006, and that blade servers fit more servers in the same area, raising power per area while lowering consumption per server. Energy management has become a priority, backing up power sources is the first step, and feeding from at least two separate sources has become mandatory. For cooling, the rule given is cooling capacity equal to the device's power draw (50 kW of cooling for a 50 kW device).

The cooling and layout section cites ANSI/TIA/EIA-942 for arranging cabinets in hot and cold aisles, a raised floor delivering cold air to vents in front of cabinets, and redundancy of air conditioners. Aisle width is given as at least 100 cm and raised floor height at least 50 cm, with floor material able to withstand 1000 kg. For cabling it recommends structured cabling, separating power and data (data under the hot aisle, power under the cold aisle) and avoiding sharp 90-degree bends.

The monitoring section covers 24/7 camera recording and monitoring of water leakage, temperature, fire, voltage changes and air quality, with notifications by e-mail or SMS. For earthquakes it discusses fixing cabinet feet and placing load-bearing pedestals. The paper dates from 2013 and is short and introductory; its figures and its descriptions of topics such as fire suppression should be read for terminology and topic discovery, not as current engineering requirements.

Key points

  1. Power demand of server rooms is stated to have doubled between 2003 and 2006.
  2. Blade servers raise consumption per area and lower consumption per server.
  3. Electrical supply should come from at least two separate sources; redundancy doubles hardware cost but is necessary.
  4. Cooling capacity is taken equal to device power: 50 kW of cooling for 50 kW consumption.
  5. Cabinets are arranged in hot and cold aisles; minimum aisle width is 100 cm.
  6. Raised floor height is at least 50 cm; the floor should withstand 1000 kg, and since current cabinets can carry 1500 kg this must also be considered.
  7. Data cables run in channels under the hot aisle and power cables under the cold aisle; inside cabinets, power and data are kept on opposite sides.
  8. Monitoring scope: water leakage, temperature, fire, voltage changes and air quality; alerts by e-mail or SMS.
  9. The paper is on pages 93-97 of the Akademik Bilişim 2013 proceedings.

Using it in design

  • Use the paper as a Turkish-language terminology and checklist introduction to data centre design topics (energy, cooling, monitoring, floor, cabling).
  • Compare and verify the hot and cold aisle, redundancy and cable separation principles against current standards before turning them into design criteria; do not make the 2013 numerical values into specifications.
  • Use the monitoring scope list (leakage, temperature, fire, voltage, air quality) as a starting draft for the BMS and DCIM sensor plan.
  • Calculate raised floor loading from the actual cabinet weight.

Who should read it

Turkish-reading engineers and students entering the data centre field, and project teams looking for a simple topic map.

Document contents

  1. Introduction
  2. Energy Use of the Data Centre
  3. Security of the Data Centre
  4. Cooling of the Data Centre
  5. Monitoring of the Data Centre
  6. Floor Construction and Cabling of the Data Centre

Publication details

Authors
Hüseyin Taner Gökmen; Ecir Uğur Küçüksille
Publisher
Akademik Bilişim 2013 / Akdeniz Üniversitesi
Year
2013
Document number
XV. Akademik Bilişim Konferansı, pp. 93–97
Document language
Turkish
Source type
Industry body
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Official publisher or university publicly accessible text; no open redistribution licence established. Review literature, not measured performance evidence. No numeric or normative cabling, floor-load or extinguishing requirement is imported.

Citation

Hüseyin Taner Gökmen; Ecir Uğur Küçüksille (2013). Veri Merkezi Tasarımı. Akademik Bilişim 2013 / Akdeniz Üniversitesi. XV. Akademik Bilişim Konferansı, pp. 93–97. https://ab.org.tr/ab13/kitap/AB2013_Bildiri_Kitap.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Redundancy scenarios in SoSo CAD

Compare normal operation with equipment failures and see served loads and capacity shortfalls in the same view.

Normal operation and failure scenario comparison in SoSo CAD

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.