Technical guideFree to read2026

How energy-efficient air filters reduce data centre power consumption

Camfil · Paul Flanagan

Camfil's April 2026 engineering article argues that low-pressure-drop filters cut fan energy in data centres where HVAC can account for up to 40% of total power use.

On this page

Overview

The article, by Camfil EMEA West regional director Paul Flanagan and dated 22 April 2026, is a manufacturer blog post. Its starting point is that HVAC can represent as much as 40% of a data centre's power use while air filters are often overlooked in cooling strategy discussions.

The core mechanism is airflow resistance. Inefficient or quickly clogging filters force HVAC units to run fans harder, which raises energy use, mechanical wear and loses cooling effectiveness. Filters engineered for low pressure drop let air through more easily and, according to the article, give immediate measurable energy savings.

The second argument concerns behaviour over time. Many standard filters degrade quickly as dust accumulates and the system compensates; advanced media keep a consistent airflow and resistance curve through the lifecycle and reduce the frequency of changeouts. The article gives no numerical saving.

For the design stage it recommends selecting filters together with engineers and equipment manufacturers. A proper analysis can reduce the plant footprint or allow more air through a space-limited footprint for extra capacity. The piece is a manufacturer's position and contains no measurements or case study.

Key points

  1. HVAC can account for up to 40% of total data centre power use.
  2. Clogged or high-resistance filters raise HVAC fan speed and energy use.
  3. Low-pressure-drop filters ease air passage and reduce fan energy.
  4. Advanced media hold airflow and resistance curves steadier over the filter life.
  5. Stable resistance reduces the frequency of filter changeouts.
  6. Selecting filters at design stage can shrink plant footprint or raise airflow in the same footprint.
  7. The article gives no numerical savings or measurements.

Using it in design

  • Request the pressure drop curve across dust loading, not only the initial value, and verify fan selection against the final resistance.
  • Carry filter pressure drop as an explicit line in the cooling unit's total static pressure budget.
  • Compare filter alternatives on lifecycle cost, calculating annual fan energy at the average filter resistance.
  • In space-limited plant rooms, check in preliminary design how lower-resistance filters change face velocity or unit size.

Who should read it

Data-centre HVAC designers and operations engineers.

Document contents

  1. Air filters directly impact airflow resistance
  2. Energy-efficient filters
  3. The bottom line

Publication details

Authors
Paul Flanagan
Publisher
Camfil
Year
2026
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Official public manufacturer source inspected. No redistribution permission established. Metadata and original brief summaries only; local files are research evidence, not a redistribution package.

Citation

Paul Flanagan (2026). How energy-efficient air filters reduce data centre power consumption. Camfil. https://www.camfil.com/en/insights/blogs/2026/reduce-energy-consumption

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Cooling capacity in SoSo CAD

Check zone heat loads, installed capacity and the capacity left with the largest unit out, as part of the design.

Zone heat loads and capacity balance in the SoSo CAD cooling workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.