High-Rise Electrical Engineering XIV: Uninterruptible Power Supply Systems
Original title Yüksek Yapılar’da Elektrik Mühendisliği-XIV: Kesintisiz Güç Kaynağı Sistemleri
TMMOB Elektrik Mühendisleri Odası İzmir Şubesi · Ahmet Becerik
An EMO Izmir branch article from October 2011 that explains the need for UPS in high-rise buildings, the IEC 62040-3 classes (VFD, VI, VFI) and the building blocks of a static UPS, in Turkish and in practical terms.
On this page
Overview
The three-page article by Ahmet Becerik starts from the sensitivity of computers and electronic data-processing systems in high-rise buildings to outages and voltage variations. It states that UPS systems act as backup power to protect critical loads from power-quality problems, that the structure chosen depends on the load's character and power, and that total operating cost should be worked out from first cost, cost from efficiency differences and maintenance expenses.
On capacity, it describes two limits: UPS energy can be sized only for enough time to shut down service computers and process-control and safety devices in a programmed way, or large enough to carry all operations until a backup source starts. The best choice is usually between the two. Long-duration supply is not suited to a UPS alone, both for battery cost and design difficulty; designing it together with an automatic generator running in parallel with the mains is presented as the best solution.
In the standards section, based on IEC 62040-3 (1999) and its CENELEC adaptation EN 50091-3, three classes are described by the dependence of output voltage and frequency on the main supply: VFD (passive standby), VI (line-interactive) and VFI (double conversion). The article summarises their advantages and limits, which power problems each handles, and the composition of a static UPS: rectifier, battery charger, battery bank, inverter, static and manual bypass, and output transformer.
The article is a short professional-chamber publication from 2011; it does not cover current standard editions or lithium batteries and has no product or cost comparison. It serves as a plain reference for settling Turkish UPS terminology and the basic classification logic.
Key points
- Static UPS systems are available from 200 VA to 50 kVA single-phase and from 10 kVA to about 4000 kVA three-phase.
- The standard is IEC 62040-3 (1999) with its CENELEC counterpart EN 50091-3; three classes are VFD, VI and VFI.
- Passive standby (VFD) is the simplest and cheapest; it protects only against outage, sag and dynamic voltage rise, and its transfer time is not zero, so it is not preferred for IT systems.
- Line-interactive (VI) came into use in the 1990s; it is cheaper than double conversion but has no frequency control and weaker protection against transients.
- Double conversion (VFI) supplies all power through the output inverter with zero transfer time and is considered ideal for sensitive loads; its drawbacks are high cost and lower efficiency.
- Of ten listed power problems, VFD handles the first three and VI five; a VFI class unit is needed to limit all ten.
- New-generation high-power UPS use 12-pulse rectifiers, input harmonic filters and PFC circuits.
- For long-duration supply, designing the UPS with an automatic generator in parallel with the mains is recommended.
Using it in design
- Set UPS capacity and autonomy between the two limits: controlled-shutdown time only, versus full time until the backup source takes over; with a generator, size autonomy to generator start time.
- Base IT and data loads on the VFI (double-conversion) class; limit VFD to loads that tolerate a short interruption.
- Select on total operating cost including efficiency differences and maintenance, not on first cost alone.
- For high-power UPS, limit input harmonics and input power factor in the specification (12-pulse rectifier, harmonic filter or PFC rectifier).
- Show the role of static and manual bypass switches in maintenance and fault scenarios on the single-line diagram.
Who should read it
Electrical engineers selecting UPS for high-rise and office buildings, and technical staff looking for an introduction to Turkish UPS classification terminology.
Document contents
- The need for UPS in high-rise buildings
- Applications tied to the UPS standard
- Standard UPS classes: passive standby, line-interactive, double conversion
- Reducing the effects of problems with a UPS
- Review of static UPS structures
Publication details
- Authors
- Ahmet Becerik
- Publisher
- TMMOB Elektrik Mühendisleri Odası İzmir Şubesi
- Year
- 2011
- Document number
- EMO İzmir Şubesi Haber Bülteni 257, s. 32–34
- Document language
- Turkish
- Source type
- Industry body
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
Yayıncının açık PDF dosyası okundu. Açık erişim yeniden dağıtım izni anlamına gelmez; yalnızca künye, özgün kısa özet ve sayfa atıfları kaydedildi. 2011 tarihli teknik açıklamadır; atıf yapılan standartların güncel baskıları ayrıca kontrol edilmelidir.
Citation
Ahmet Becerik (2011). Yüksek Yapılar’da Elektrik Mühendisliği-XIV: Kesintisiz Güç Kaynağı Sistemleri. TMMOB Elektrik Mühendisleri Odası İzmir Şubesi. EMO İzmir Şubesi Haber Bülteni 257, s. 32–34. https://www.emo.org.tr/emoyayin/dosya/11970
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.