StandardPaid2024

Information technology - Data centre facilities and infrastructures - Part 6: Security systems

ISO/IEC · ISO/IEC JTC 1

The standard on physical security of data centres following the Part 1 classification, with requirements against unauthorized access, intrusion, internal fire and environmental events.

This document is sold by ISO/IEC and is available from the publisher’s site. SoSo CAD does not sell or distribute it; this page holds only catalogue details and our own summary.

On this page

Overview

ISO/IEC 22237-6 covers the physical security of data centres and follows the classification in Part 1 of the ISO/IEC 22237 series. It assigns designations to the data centre spaces defined in Part 1 and sets requirements according to the protection level of each space. The first edition, published in 2024, runs to 34 pages and replaces the 2018 technical specification ISO/IEC TS 22237-6.

The requirements fall into several threat groups: protection against unauthorized access through both organizational and technological solutions; protection against intrusion; protection against fires igniting within data centre spaces; and protection against internal non-fire environmental events and external events that affect the defined protection level. Constructional requirements are given by reference to ISO/IEC 22237-2. This grouping means security design has to consider both physical and organizational measures together.

The document is a paid standard, and only the publisher's public catalogue abstract and product data were used here; the full text was not read. Details of class levels, quantitative values and test methods must therefore be taken from the original. The standard treats security as part of a classification of spaces and protection levels rather than as a matter of individual products.

Key points

  1. Provides designations for the data centre spaces defined in ISO/IEC 22237-1.
  2. Requires protection against unauthorized access through organizational and technological solutions, and against intrusion.
  3. Requires protection against internal fire events igniting within data centre spaces.
  4. Requires protection against internal non-fire and external environmental events, according to the defined protection level.
  5. Constructional requirements are given by reference to ISO/IEC 22237-2.
  6. Edition 1 was published 2024-02-19, runs to 34 pages and replaces ISO/IEC TS 22237-6:2018.

Using it in design

  • Tag each room in the floor plan with a protection class and check that access-control zones nest correctly, so a higher-class room is not reachable except through lower-class rooms.
  • Feed the room classes into the defaults for fire detection and suppression.
  • Document separate protection decisions for intrusion, internal fire and environmental events in the design report.

Who should read it

Engineers and security consultants designing physical security, fire protection and building layout for data centres.

Related standards

  • EN 50600-2-5
  • ISO/IEC 22237-2
  • NFPA 75

Publication details

Authors
ISO/IEC JTC 1
Publisher
ISO/IEC
Year
2024
Document number
ISO/IEC 22237-6:2024
Document language
English
Source type
Standard
Access
Paid; available from the publisher
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

Paid standard. Record built only from the publisher's public catalogue abstract and product metadata; full text not redistributed.

Citation

ISO/IEC JTC 1 (2024). Information technology - Data centre facilities and infrastructures - Part 6: Security systems. ISO/IEC. ISO/IEC 22237-6:2024. https://webstore.iec.ch/en/publication/92578

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Standards pre-assessment in SoSo CAD

Run TS EN 50600 and Tier pre-checks on the model, with missing inputs and items for engineering review listed separately.

Selected rule packs and findings in the SoSo CAD standards panel

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.