The Exide Sprinter P/XP VRLA battery-block data sheet separates ten-hour from twenty-hour capacity and gives a ten-minute constant-power rating per block.

On this page

Overview

Exide Technologies' Sprinter P/XP data sheet gives the ratings of VRLA battery blocks: capacity at defined discharge rates and constant-power performance. The rating table distinguishes ten-hour capacity from twenty-hour capacity and specifies ten-minute power per block.

These are component ratings and do not establish a complete cabinet configuration. For a cabinet the number of blocs, DC bus voltage and load profile must be calculated separately.

Key points

  1. The data sheet covers VRLA battery blocks.
  2. The table gives ten-hour and twenty-hour capacity in separate columns.
  3. Ten-minute power per block is specified.
  4. Capacity depends on the defined discharge rates.
  5. Component ratings do not establish a complete cabinet configuration.

Using it in design

  • For UPS back-up, compare the ten-minute block power with the watts per cell derived from the UPS load.
  • Do not mix the ten-hour and twenty-hour capacity columns; compare models within the same column.
  • Calculate the number of blocs from the DC bus voltage and document the cabinet configuration separately.

Who should read it

Electrical designers selecting UPS battery banks and engineers writing specifications.

Publication details

Authors
Exide Technologies
Publisher
Exide Technologies
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Exide Technologies Exide Sprinter P/XP technical data sheet. Exide Technologies. https://www.exidegroup.com/eu/en/document/sprinter-pxp-datasheet

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.