Inform general catalogue 2020
Inform
The online UPS section of Inform's 2020 general catalogue: model capacities, input and output data, battery and physical data for the Sinus EVO, Sinus EVO RM, DSP EVO, DSP Multipower and DSP Flexipower series.
On this page
Overview
The catalogue covers a much wider range (line-interactive and online UPS, modular UPS, batteries and battery cabinets, voltage regulators, rectifiers, medical isolated power systems, the Info-STS static transfer switch and frequency converter); this summary rests on the five online UPS series only. All of them have true sine output with double-conversion technology, microprocessor control, LCD, cold start, ECO mode, frequency converter mode and generator compatibility. Standard communication is USB, RS-232 and EPO, with optional SNMP and relay card; warranty is 2 years.
Sinus EVO comprises 1, 2 and 3 kVA single-phase in and out models with output power factor 0.9, input power factor 0.98 or more (active PFC), operating voltage range 110-300 VAC and frequency 50/60 Hz ±5 percent. Sinus EVO RM is the rack version of the same capacities. DSP EVO has 6 kVA / 5.4 kW and 10 kVA / 9 kW models: input power factor 0.99 or more, THDi 5 percent or less, output power factor 0.9, ±1 percent voltage regulation, efficiency 90 percent or more, 20 standard 12 V 7 Ah VRLA batteries and 0 ms transfer.
DSP Multipower has six discrete models: DSPMP-1105 (5 kVA), 1106 (6) and 1110 (10) single phase, and DSPMP-3110 (10), 3115 (15) and 3120 (20) with three-phase input. Overall efficiency is 90, 91 and 93 percent or more and eco-mode efficiency is 97 percent or more; rack power modules are 2U, 3U and 5U, and the tower type is 290 x 650 x 750 mm and 60 kg. DSP Flexipower is given as 3, 5, 6, 8 and 10 kVA single phase and 10 kVA with three-phase input; efficiency is 90 or 92 percent or more, and apart from the 3 kVA unit it has high input power factor (>0.99) and a standard manual bypass.
Output power or physical values that are not stated must be treated as unknown; the model capacity columns establish the available UPS variants.
Key points
- Sinus EVO and Sinus EVO RM: 1, 2, 3 kVA, single-phase in and out, output power factor 0.9, input 110-300 VAC.
- DSP EVO: 6 kVA / 5.4 kW and 10 kVA / 9 kW; input 120-276 VAC, input power factor 0.99 or more, THDi 5 percent or less.
- DSP EVO output: power factor 0.9, ±1 percent regulation, THDv 3 percent (linear) and 5 percent (non-linear), efficiency 90 percent or more.
- DSP EVO battery: 16/18/20 adjustable, standard 20 x 12 V 7 Ah VRLA; 90 percent charge in 8-10 hours; transfer 0 ms.
- DSP EVO overload: 10 min at 105-110 percent, 1 min at 110-130 percent, above 130 percent transfers to bypass.
- DSP Multipower: DSPMP-1105, 1106, 1110 (5, 6, 10 kVA, single phase) and DSPMP-3110, 3115, 3120 (10, 15, 20 kVA, three-phase input).
- DSP Multipower efficiency 90 / 91 / 93 percent or more; eco mode 97 percent or more.
- DSP Flexipower: 3, 5, 6, 8, 10 kVA single phase and 10 kVA three-phase input; efficiency 90 or 92 percent or more; input power factor >0.99 except 3 kVA.
- Operating temperature 0-40 C; 20-25 C recommended for long battery life.
Using it in design
- Record each series by kW as well as kVA (for example 6 kVA = 5.4 kW) and by input phase (1 or 3).
- Use only the discrete models published in the catalogue; make no assumptions for unstated power or physical fields.
- In rack layout, treat the Multipower 2U, 3U and 5U module heights and the 4U/6U versions with batteries separately.
- Use input THDi and power factor in generator sizing.
- State in the purchase specification that units for parallel operation must be ordered as parallel units.
Who should read it
Designers and buyers selecting single-phase-output 1-20 kVA online UPS units for small and medium data rooms.
Document contents
- Contents (line-interactive, online, modular UPS, batteries, regulators, rectifiers, medical isolated power, STS, frequency converter)
- Sinus EVO
- Sinus EVO RM
- DSP EVO
- DSP Multipower
- DSP Flexipower
Publication details
- Authors
- Inform
- Publisher
- Inform
- Year
- 2020
- Document language
- Turkish
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Inform (2020). Inform general catalogue 2020. Inform. https://www.inform.com.tr/files/informkatalog2020.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.