Amaron Quanta Medium VRLA Batteries (26-200 Ah)
Original title Amaron Quanta medium VRLA technical downloads
Amara Raja
Amara Raja's Amaron Quanta Medium VRLA product page: AGM valve-regulated lead-acid batteries for UPS and critical power use, offered in ten capacities from 26 to 200 Ah.
On this page
Overview
The page presents the Amaron Quanta Medium VRLA series from Amara Raja Energy & Mobility as a UPS battery. The maker positions the series as a comprehensive range for all critical power applications and a preferred choice of well-known UPS manufacturers. Data sheets can be downloaded for 26, 65, 75, 84, 100, 120, 130, 150, 160 and 200 Ah models, grouped under five capacity ranges.
Performance claims include a patented heavy-duty alloy grid for design life and cycle life, high-rate discharge with low internal resistance, thicker grids and higher separator compression, low-permeability PPCP containers that prevent water loss, high-integrity inter-cell welds and a high-compression AGM separator with more than 98% oxygen recombination. The maker cites the Radgrid profile, the patented Orifice paste process and cast-on-strap design as industry firsts.
Target applications are IT and ITES installations, banking infrastructure, manufacturing, and hospitals and testing laboratories. The page is a series introduction and data sheet gateway; dimensions, weights, design life and discharge tables are not on the page and sit in the model data sheets.
Key points
- Series: Amaron Quanta Medium VRLA, for UPS and critical power.
- Ten capacities: 26, 65, 75, 84, 100, 120, 130, 150, 160 and 200 Ah.
- AGM separator with more than 98% oxygen recombination.
- Patented heavy-duty alloy grid, Radgrid profile, Orifice paste process, cast-on-strap.
- PPCP container with low permeability prevents water loss.
- Target sectors: IT/ITES, banking, manufacturing, hospitals and laboratories.
- Model data sheets and warranty terms are downloaded from the page.
Using it in design
- Use the page's capacity ranges as a starting point and read discharge tables from the model data sheet.
- In the battery specification, list grid alloy, separator type and container material (PPCP) as separate items.
- Review the warranty terms separately in the procurement decision; the page does not state them.
- Confirm that the series is on the UPS manufacturer's approved battery list.
Who should read it
Electrical designers selecting UPS battery blocks and engineers writing purchase specifications.
Document contents
- Amaron Quanta Medium VRLA
- Performance edge
- Key applications
- Data sheets and warranty terms
Publication details
- Authors
- Amara Raja
- Publisher
- Amara Raja
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Amara Raja Amaron Quanta medium VRLA technical downloads. Amara Raja. https://amaronquanta.com/product/medium-vrla/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.