GS Yuasa BACSTAR-LIM renewed lithium-ion UPS product profile, 2018-03-29
GS Yuasa
GS Yuasa's news release of 29 March 2018 announces the renewed BACSTAR-LIM series of UPS systems equipped with industrial lithium-ion batteries. The series offers seven ratings from 30 to 200 kVA (24 to 160 kW), and one battery bank of eight LIM50EN-12 modules stores 16.8 kWh.
On this page
Overview
The release reports that GS Yuasa Corporation has launched a renewed BACSTAR-LIM series. The new version is fitted with LIM50EN series industrial lithium-ion batteries, which perform better than the LIM50E series used in the previous product. The manufacturer states that the change optimised the control system, reduced the size and weight of the batteries and improved cost performance. The target users are sites with limited floor loading and installation space.
Three features are highlighted. First, high-energy lithium-ion batteries cut weight and installation space markedly compared with a system using lead-acid batteries. Second, battery voltage, temperature and discharge amount, together with alarms, are managed centrally on a cell-module basis, which lightens the measurement work during regular inspections. Third, the units leave the plant with the batteries installed, which simplifies work at the installation site and shortens the process.
The product profile table gives seven rated outputs: 30, 40, 50, 75, 100, 150 and 200 kVA, with active power of 24, 32, 40, 60, 80, 120 and 160 kW, that is an output power factor of 0.8. The input is three-phase three-wire at 200 or 210 V ± 10%. The output is three-phase three-wire at 200 or 210 V, and a single-phase two-wire output is offered on part of the range. For capacities of 20 kVA and below the reader is asked to contact the manufacturer.
Environmental conditions are an operating temperature of -10 °C to 40 °C, relative humidity of 25 to 85% without condensation and an altitude of 1000 m or below, installed indoors where harmful gas, salt and dust are limited. On the battery side the module is the LIM50EN-12, with 8 modules per bank and 16.8 kWh stored per bank. The voltage levels reflect the Japanese market. The release carries no efficiency, autonomy, dimension or weight figures; those are in the product catalogue.
Key points
- Seven rated outputs: 30, 40, 50, 75, 100, 150 and 200 kVA, corresponding to 24, 32, 40, 60, 80, 120 and 160 kW.
- AC input: three-phase three-wire, 200 or 210 V ± 10%.
- AC output: three-phase three-wire at 200 or 210 V; single-phase two-wire output on part of the range.
- Battery: LIM50EN-12 industrial lithium-ion module, 8 modules per bank, 16.8 kWh per bank. That figure is the energy of one bank, not of the whole UPS system.
- Operating temperature -10 °C to 40 °C, relative humidity 25 to 85% (no condensation), altitude 1000 m or below.
- Battery voltage, temperature, discharge amount and alarms are monitored centrally per cell module.
- Units ship from the plant with batteries installed; capacities of 20 kVA and below are handled on request.
Using it in design
- Use an output power factor of 0.8 in load calculations: the largest 200 kVA model delivers 160 kW of active power.
- Base the autonomy calculation on 16.8 kWh per bank and determine the number of banks for the required time from manufacturer data.
- The 200 or 210 V three-phase three-wire input and output require a transformer on 400 V systems; consider the series only for sites that use this voltage level.
- In existing buildings with limited floor loading, compare weight and footprint against a lead-acid option, taking the values from the product catalogue.
- Keep the UPS room design temperature within -10 °C to 40 °C and humidity within 25 to 85%, and ask the manufacturer for derating information at sites above 1000 m.
Who should read it
Electrical designers selecting medium-power UPS systems with lithium-ion batteries, and engineers running retrofit projects in buildings with limited floor loading.
Document contents
- GS Yuasa Launches Renewed Uninterruptable Power Supply BACSTAR-LIM Series Equipped with Industrial-use Lithium-ion Batteries
- Features: reduced floor load and space required for installation, simplified maintenance, installed with storage batteries when shipped from the plant
- Product profile 1: Requirement table of the uninterrupted power supply equipment
- Product profile 2: Industrial-use lithium-ion batteries
- Images
Publication details
- Authors
- GS Yuasa
- Publisher
- GS Yuasa
- Year
- 2018
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
GS Yuasa (2018). GS Yuasa BACSTAR-LIM renewed lithium-ion UPS product profile, 2018-03-29. GS Yuasa. https://www.gs-yuasa.com/en/newsrelease/article.php?ucode=gs180416182417_535
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.