Luminous LD30KH-PRO / LD40KH-PRO User Manual, Section 6 Specifications
Original title Luminous LD30KH-PRO / LD40KH-PRO user manual, section 6 specifications
Luminous
Luminous LD30KH-PRO and LD40KH-PRO are 3U three-phase online UPS units at 30 and 40 kVA/kW with power factor 1, 95.5% efficiency in AC mode, 0 ms transfer and a parallel option.
On this page
Overview
The manual covers safety, installation, operation, LCD settings, fault codes, troubleshooting, storage and maintenance for the Luminous LD30KH-PRO (30 kVA / 30 kW) and LD40KH-PRO (40 kVA / 40 kW) three-phase online UPS models. The safety section stresses connection to a TN earthing system, a backfeed protection system per EN/IEC 62040-1, an integral emergency shutoff switch and mandatory earthing because of high leakage current.
In the section 6 table, input is three-phase plus neutral with power factor ≥0.99; low-line loss voltage is 176 VAC (phase-neutral) ±3% at full load and 110 VAC at 50% load, and high-line loss is 276 VAC at full load. Output voltage is 360/380/400/415 VAC (phase-phase), regulation ±1%, THD ≤2% on linear load and ≤5% on non-linear load. Overload in AC and battery mode is 60 minutes at 100 to 110%, 10 minutes at 110 to 125%, 1 minute at 125 to 150% and immediate above 150%. Line to battery transfer is 0 ms; if phase lock fails, inverter to bypass has an interruption under 4 ms.
Efficiency is 95.5% in AC mode and 94.5% in battery mode. Battery count is adjustable from 32 to 40, charging voltage ±218.4 VDC and maximum charging current 12 A (adjustable). Dimensions are 680 x 438 x 133 mm (3U), weight 29 and 30 kg and noise 65 and 70 dB. Operation is 0 to 40 °C with battery life falling above 25 °C; above 1000 m, power derates 1% per 100 m. The parallel model requires identically configured UPS units connected with parallel and shared-current cables.
Key points
- Models: LD30KH-PRO 30 kVA / 30 kW; LD40KH-PRO 40 kVA / 40 kW; 3U height.
- Input: three-phase plus neutral; power factor ≥0.99; low-line loss 176 VAC (full load), 110 VAC (50% load).
- Output 360/380/400/415 VAC (phase-phase); regulation ±1%; THD ≤2% (linear), ≤5% (non-linear); crest factor 3:1 max.
- Overload: 60 min at 100 to 110%, 10 min at 110 to 125%, 1 min at 125 to 150%.
- Transfer: line to battery 0 ms; inverter to bypass <4 ms interruption if phase lock fails; ECO mode on mains loss <10 ms.
- Efficiency: 95.5% in AC mode; 94.5% in battery mode.
- Battery count adjustable 32 to 40; ±218.4 VDC; charging current up to 12 A.
- Noise 65 dB (30 kVA) and 70 dB (40 kVA); IP20; 1% derating per 100 m above 1000 m.
Using it in design
- Add the TN earthing requirement and an EN/IEC 62040-1 backfeed protection contactor to the single-line diagram; the unit has no standard backfeed protection.
- With full-load low-line loss at 176 VAC, evaluate battery use during voltage sags against that threshold.
- Size the battery string for 32 to 40 units and a 12 A charging current; keep the battery room below 25 °C.
- For parallel installations, all units must be parallel models of the same configuration; include phase sequence and output voltage difference (under 1.5 V) in the commissioning checklist.
- Check rack load capacity for the 3U, 29 to 30 kg units and the noise level (65 to 70 dB).
Who should read it
Electrical engineers and site teams installing and commissioning mid-range three-phase UPS units.
Document contents
- Safety and EMC instructions
- Installation and operation
- Operations
- Troubleshooting
- Storage and maintenance
- Specifications
Publication details
- Authors
- Luminous
- Publisher
- Luminous
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Luminous Luminous LD30KH-PRO / LD40KH-PRO user manual, section 6 specifications. Luminous. https://5.imimg.com/data5/SELLER/Doc/2025/6/522760475/JK/PJ/BT/44976779/luminous-make-ld30kh-pro-30-kva-3-phase-on-line-ups.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.