Rocket industrial battery catalogue (Sebang, 2019)
Original title Rocket industrial battery catalogue
Sebang Global Battery
Sebang's (Rocket) 2019 catalogue industrial section lists ESP, ESG, VGS, CGS and RP sealed lead-acid series for UPS and standby power; the ESP 12 V table gives 40-200 Ah capacities at five discharge rates and dimensions.
On this page
Overview
The catalogue covers the product range and corporate profile of South Korea's Sebang (Rocket Battery brand) across automotive, industrial, motive power and recycling. The text is in Korean. The company states it was founded in 1952, exports to over 130 countries and exported 680 million dollars in 2018. The document is a historical 2019 catalogue.
The industrial section covers series for UPS systems, telecom and renewable energy backup. The ESP series uses high-purity alloy and new plate production, multi-stage plate treatment and special organic fibre, and is said to extend life by reducing self-discharge. The ESG series is a maintenance-free sealed type suited to float service with an explosion-resistant safety valve. VGS is a gel-electrolyte series whose uses include internet data centres (IDC).
The CGS series removes water topping through gas recombination, can be arranged horizontally or vertically and carries a special relief valve. The RP series uses full-calcium alloy to limit capacity loss and is listed for UPS, switchgear, generators and fire systems. The PS series is presented as a vented battery with a transparent case for visual inspection.
The ESP 12 V table gives capacities at 10, 5, 3, 1 and 0.5 hour rates (end voltages 1.8, 1.7, 1.67, 1.6 and 1.6 V per cell), dimensions and weight. For example, ESP 100-12 is 100 Ah (10 h), 65 Ah (1 h), 442 x 168 x 237 mm and 30 kg. The document states table values may change without notice.
Key points
- Sebang was founded in 1952 and exports to over 130 countries; 680 million dollars of exports in 2018.
- Industrial series: ESP, ESG, VGS (gel), CGS, RP and vented PS.
- ESP 12 V models: 40, 65, 93 (100H), 100, 120, 130, 150 and 200 Ah (10-hour).
- ESP 100-12: 100 Ah at 10 h, 92 Ah at 5 h, 83 Ah at 3 h, 65 Ah at 1 h, 50 Ah at 0.5 h.
- ESP 200-12: 200 Ah (10 h), 520 x 269 x 237 mm, 59 kg; ESP 40-12: 40 Ah, 197 x 165 x 174 mm, 12 kg.
- End voltages: 1.8 V/cell for 10 h, 1.7 V for 5 h, 1.67 V for 3 h, 1.6 V for 1 h and 0.5 h.
- The VGS gel series limits hazard if the case breaks as the electrolyte gels; CGS is maintenance-free through gas recombination.
- The document is a historical 2019 catalogue.
Using it in design
- For backup time, use the correct discharge duration and end voltage from the hourly capacity table; the 10-hour Ah value falls to about 65% at a 1-hour discharge (65 Ah for ESP 100-12).
- Match block dimension and weight (ESP 200-12: 59 kg) to handling and rack loading in the layout.
- When choosing UPS battery type, compare the maintenance and ventilation needs of sealed VRLA (ESG, CGS, RP), gel (VGS) and vented (PS) options.
- Because this is a historical catalogue, confirm current production and model codes with the manufacturer.
Who should read it
Electrical engineers selecting lead-acid batteries for UPS and standby power or updating existing installations.
Document contents
- Our message and highlights
- Automotive range
- Industrial range (ESP, ESG, VGS, CGS, RP, PS)
- Motive power range
- Recycling and sustainability management
Publication details
- Authors
- Sebang Global Battery
- Publisher
- Sebang Global Battery
- Year
- Year not stated
- Document language
- Korean
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Sebang Global Battery Rocket industrial battery catalogue. Sebang Global Battery. https://www.gbattery.com/static/web/images/product/SEBANG%20ROKET%20Br%202019.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.