Solite SLD industrial standby battery range

Original title SLD industrial standby battery range

Hyundai Sungwoo Solite

Hyundai Sungwoo Solite's SLD range of maintenance-free, sealed lead-acid industrial batteries, offered as SLD 2V, SLD 12V and SLD small groups with a complete-maintenance-free (CMF) construction.

On this page

Overview

The source is the industrial battery product page of the Solite brand of South Korea's Hyundai Sungwoo Holdings. The page presents the SLD battery as a maintenance-free, leak-proof sealed (valve-regulated) battery. Products are grouped as SLD 2V, SLD 12V and SLD small, and an SLX product information section is also listed.

The manufacturer highlights three properties. The first is the use of an ultra-low-resistance PE separator, which gives strong starting (high-current) capability even in severe cold. The second is Solite's advanced rolling technology: improved corrosion behaviour is said to extend service life.

The third is the fully sealed construction. The internal design keeps electrolyte loss and gas generation very small, so the battery is offered as complete maintenance free (CMF). A filter plug in the cover vent is said to prevent electrolyte leakage and so guard against rupture, body corrosion and environmental pollution.

The page embeds a model-level capacity and dimension table as an image; its capacity header is the ten-hour discharge rate. When comparing capacities with other sources, check the discharge-rate label. The page introduces the product groups and general construction, and the detailed numbers sit in the product table.

Key points

  1. Product groups: SLD 2V, SLD 12V and SLD small; plus the SLX series.
  2. Construction: maintenance-free, leak-proof sealed battery; CMF (complete maintenance free).
  3. Ultra-low-resistance PE separator for strong starting in cold conditions.
  4. Advanced rolling technique for improved corrosion behaviour and longer life.
  5. Filter plug in the cover vent prevents electrolyte leakage.
  6. The model table covers ten models; its capacity header is the ten-hour rate.

Using it in design

  • When comparing battery capacities across manufacturers, separate the 10-hour rate (C10) from the discharge rates that match UPS autonomy.
  • Verify the capacity needed for UPS backup time from the manufacturer's short-duration discharge (kW per cell) table rather than deriving it from C10.
  • A sealed construction reduces ventilation needs but does not remove them; do the battery room ventilation calculation under the applicable standards.
  • Obtain design life and operating temperature data separately from the product table, as this page does not give them numerically.

Who should read it

Electrical engineers selecting industrial and data-centre battery systems and procurement teams evaluating battery suppliers.

Document contents

  1. SLD battery (industrial batteries)
  2. SLD 2V / SLD 12V / SLD small
  3. Strong starting capability
  4. Extended life
  5. Fully sealed structure (CMF)
  6. SLX product information

Publication details

Authors
Hyundai Sungwoo Solite
Publisher
Hyundai Sungwoo Solite
Year
Year not stated
Document language
Korean
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Hyundai Sungwoo Solite SLD industrial standby battery range. Hyundai Sungwoo Solite. https://www.solite.co.kr/industrial_sld.html

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.