Yuasa SWL+ industrial VRLA battery brochure

Original title SWL+ high-rate standby battery technical brochure

Yuasa

GS Yuasa's SWL+ industrial VRLA battery series: 15-year design life at 20 °C (EUROBAT 12+ years, Very Long Life), 12 years at 25 °C, UL 1989 certified and 98% recyclable.

On this page

Overview

The brochure (LIT084) presents the SWL+ battery, the next evolution of GS Yuasa's SWL range. The series is industrial VRLA batteries designed for critical standby and high-rate discharge applications and made in the manufacturer's UK factory. In existing SWL installations it can be fitted as a direct replacement for UK-manufactured SWL batteries.

The main change is extended design life: 15 years at 20 °C, EUROBAT classified as 12+ years 'Very Long Life', and 12 years at 25 °C. The manufacturer states that this allows 25 °C room temperatures and so reduces capital and energy cost. Technology includes a hybrid of primary pure lead and recycled alloy, and HT Element X Alloy, which reduces positive grid corrosion and water loss.

On performance, high-rate capacity ratings are optimised; the series also offers high energy density, good recovery from deep discharge, a valve-regulated maintenance-free design with gas recombination, and installation in various positions except inverted. Standard cases meet UL94:HB and UL94:V0 flame-retardant options are available. The batteries are 98% recyclable and subject to 100% quality inspection with guaranteed capacity.

The product table lists 6 V and 12 V models from SWL+800 to SWL+4300. Power per cell for 10 minutes (to 1.6 V per cell at 20 °C) is 133 W for the 12 V SWL+800(FR) and 716.8 W for the SWL+4300(FR); typical weights run from 9.8 kg to 49.2 kg. Charts in the brochure show SWL+ with a longer time to end of life than SWL and two competitors in the IEC 60896-21 clause 6.16 impact stress temperature test at 55 °C.

Key points

  1. Design life 15 years at 20 °C, 12 years at 25 °C; EUROBAT 12+ years Very Long Life.
  2. HT Element X Alloy reduces positive grid corrosion and water loss; hybrid pure lead construction.
  3. UL 1989 certified; made in ISO and UKAS certified facilities; 100% quality inspection.
  4. Standard case UL94:HB, optional UL94:V0 (FR) flame retardant.
  5. 98% recyclability; made in the UK factory.
  6. Model range SWL+800 to SWL+4300; 12 V and 6 V.
  7. 10 min power: SWL+800(FR) 133 W, SWL+4300(FR) 716.8 W (1.6 V/cell, 20 °C).
  8. Typical weight 9.8-49.2 kg; installable in various positions except inverted.
  9. Direct replacement for UK-made SWL batteries in existing installations.

Using it in design

  • Compare the 20 °C and 25 °C life values (15 and 12 years) to optimise cooling cost against battery replacement interval together.
  • For UPS autonomy use the 10-minute W per cell figure (1.6 V/cell); for example 716.8 W for the SWL+4300.
  • Match the case fire class (HB or V0 FR) to the battery room fire specification and insurance requirements.
  • Use weight (9.8-49.2 kg) and dimensions for rack layout; installation in any position except inverted is possible.
  • When refreshing an existing SWL installation, confirm compatibility (direct replacement for UK-made SWL) and torque values (2.5-6.0 Nm).

Who should read it

Electrical designers selecting UPS battery systems, battery room operators and engineers planning data-centre refurbishment projects.

Document contents

  1. Extended design life and EUROBAT classification
  2. Hybrid pure Lead and HT Element X Alloy technology
  3. Design life comparison charts (IEC 60896-21, 55 °C)
  4. Built on SWL foundations (energy density, recovery, VRLA, orientation, flame retardancy)
  5. Product data table (SWL+800 to SWL+4300)

Publication details

Authors
Yuasa
Publisher
Yuasa
Year
Year not stated
Document number
LIT084
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Yuasa SWL+ high-rate standby battery technical brochure. Yuasa. LIT084. https://www.yuasa.com/media/akeneo_connector/asset_files/L/I/LIT084_SWL__flyer_ENG_web_67e9.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.