Zhonhen Medium/Micro IDC Power System: HVDC and distributed power

Original title Zhonhen Medium/Micro IDC Power System

Zhonhen

Zhonhen offers a 240/336 VDC HVDC system for medium and micro data centres (overall efficiency 98% or 96%) and a 3U/6U distributed 240 VDC power system with lithium battery above 94% efficiency.

On this page

Overview

The Zhonhen product page presents two power architectures for medium and micro internet data centres (IDC): HVDC (high-voltage DC) for centralised supply and DPS for distributed supply. HVDC is described as a new type of DC uninterruptible power supply system. The document is a product page; it contains no full model code or system rating and should not be treated as an AC UPS.

The HVDC system includes a 240 V/336 V DC power system and suits new IDC rooms with 204-288 VDC or 300-400 VDC supply; it can be prefabricated or customised to IDC size. The page emphasises higher efficiency, smaller floor area and lower investment cost. Overall operating efficiency can reach 98% (or 96%); charging-current detection accuracy in the battery loop is 2 A or better; 10 kVac input transformer rectification is integrated with AC/DC output distribution. Battery availability is 100%.

The distributed power system is a compact standard 19-inch design 3U/6U high and includes a 240 VDC power supply and lithium battery. Both the power supply and the battery are modular and hot-swappable. System efficiency is above 94%; a single lithium battery supports 2.5 kW discharge for up to 12 minutes; protection class is IP20; rack density increases by 15-25%.

In reference projects the Tencent Kunshan GDS project (10 kV to 240 Vdc + 380 Vac power system) cut investment cost by 20%, operating cost by 2% and power distribution equipment area by 50%. At Alibaba Zhangbei, 240 V HVDC reduces the losses of traditional AC-DC-AC conversion and improves PUE; the Tencent Tianjin and Hunan Mobile projects show about 8% total energy saving; at Baidu a distributed prefabricated design shortens construction time by 50%.

Key points

  1. HVDC: 240/336 VDC; for IDC rooms with 204-288 VDC or 300-400 VDC supply.
  2. HVDC overall operating efficiency up to 98% (or 96%); battery-loop charging-current detection accuracy 2 A or better.
  3. Distributed power system: 3U/6U, 19 inch, 240 VDC power and lithium battery; efficiency above 94%.
  4. A single lithium battery supports 2.5 kW for up to 12 minutes; IP20; rack density up 15-25%.
  5. Tencent Kunshan GDS: investment 20% lower, operating cost 2% lower, power equipment area 50% lower.
  6. Tencent Tianjin and Hunan Mobile: about 8% total energy saving.
  7. Baidu Baoding: distributed prefabricated design shortens construction time by 50%.

Using it in design

  • When assessing 240/336 VDC HVDC as an alternative to AC UPS in medium and micro IDCs, verify the DC input of the IT equipment (204-288 VDC or 300-400 VDC).
  • Request the efficiency claims (98% / 96% and 94%) with load points from the manufacturer; the page gives none.
  • Plan rack layout and ventilation for the 15-25% rack density increase and the modular 3U/6U form.
  • Set the autonomy scenario by comparing the distributed system's 2.5 kW for 12 minutes with generator start time.
  • Do not treat the reference project savings as guaranteed targets for your own project.

Who should read it

Electrical designers and operators evaluating DC power architecture in medium and micro data centres.

Document contents

  1. Power supply system for medium/micro IDCs
  2. Zhonhen HVDC power supply
  3. Zhonhen distributed power supply system
  4. Our success stories

Publication details

Authors
Zhonhen
Publisher
Zhonhen
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Zhonhen Zhonhen Medium/Micro IDC Power System. Zhonhen. https://www.zhonhen.com/medium-micro-idc

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.