JOVYATLAS JOVYSTAR COMPACT M/L Technical Brochure (30-500 kVA UPS)

Original title JOVYATLAS JOVYSTAR COMPACT M/L technical brochure, 11.2019, pp.1–2

JOVYATLAS

JOVYATLAS's 11.2019 brochure presents the 30-500 kVA three-phase JOVYSTAR COMPACT M/L UPS range with THDI below 3%, online efficiency above 95% and ECO efficiency above 98%.

On this page

Overview

The brochure introduces the three-phase JOVYSTAR COMPACT series from the German manufacturer JOVYATLAS. The series operates as online double conversion and spans 30 to 500 kVA: COMPACT M models are 30, 40, 60, 80, 100, 125 and 160 kVA, and COMPACT L models are 200, 250, 300, 400 and 500 kVA. Functional units are mounted vertically, so the footprint is small.

The rectifier is a PFC type with IGBT technology; input power factor is about 1 and rectifier THDI is below 3% at rated operation. The manufacturer states that this low THDI allows smaller generator sizing than thyristor rectifiers. An integrated control system selects the optimal operating mode; on-line and ECO mode (M and L) are available, plus UHE mode (COMPACT L only).

Efficiency at nominal load is above 95% in on-line mode, above 97% in battery mode, above 98% in ECO mode and above 99% in UHE mode. Output voltage is 3×400 V/230 V at 50/60 Hz; output THDI is below 1% on linear load and below 5% on non-linear load. Inverter overload is 10 minutes at 125%, 30 seconds at 125-150% and 10 ms above 150%; the bypass carries 150% permanently.

Up to 6 UPS can be paralleled; in parallel operation active current sharing takes both active and reactive power into account. Class is VFI SS 111 and protection degree IP 20. Noise is below 57 dB(A) on COMPACT M and 60 dB(A) on COMPACT L. Weight without batteries runs from 120 kg (M 30) to 1,250 kg (L 500); battery cabinets for long autonomy are available on request.

Key points

  1. COMPACT M: 30, 40, 60, 80, 100, 125, 160 kVA; COMPACT L: 200, 250, 300, 400, 500 kVA.
  2. PFC rectifier, input power factor about 1; rectifier THDI below 3%.
  3. Efficiency: on-line above 95%, battery above 97%, ECO above 98%, UHE (L only) above 99%.
  4. Output 3×400 V/230 V; THDI below 1% (linear) and below 5% (non-linear).
  5. Inverter overload: 10 min at 125%, 30 s at 125-150%, 10 ms above 150%; bypass 150% permanent.
  6. Output ±5% for a dynamic load step (20-100-20%); static ±1%.
  7. Up to 6 units in parallel; active and reactive power sharing.
  8. Class VFI SS 111; IP 20; noise <57 dB(A) (M) and <60 dB(A) (L).
  9. Weight without batteries 120-1,250 kg; battery cells 360/372; battery temperature 0-25 °C (optimum 20 °C).

Using it in design

  • Use the low THDI and near-unity input power factor in generator sizing.
  • Design the battery room to hold about 20 °C; the permitted battery range is 0-25 °C.
  • If ECO or UHE mode will be used, compare the reduced protection in those modes with load sensitivity.
  • Calculate floor loading from the weight-without-batteries table (120-1,250 kg).
  • Plan paralleling of up to 6 units and the shared-current option for redundancy.

Who should read it

Data-centre and industrial electrical engineers specifying mid- to large-rating three-phase UPS.

Document contents

  1. Online UPS systems
  2. High efficiency by innovative technology
  3. Types, dimensions and weights without batteries
  4. Technical data: output, input, efficiency, battery, setting
  5. Communication

Publication details

Authors
JOVYATLAS
Publisher
JOVYATLAS
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

JOVYATLAS JOVYATLAS JOVYSTAR COMPACT M/L technical brochure, 11.2019, pp.1–2. JOVYATLAS. https://jovyatlas.com/download_file/view/0ff59fe9-0cd9-4304-a5d3-a2fc1c940f69/336

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.