AC/DC Elektronik AS Series 6 kVA and 10 kVA UPS Product Page
Original title AC/DC AS series 6 kVA and 10 kVA manufacturer product listing
AC/DC Elektronik
Product page for the domestically made AS series 6 and 10 kVA single-phase double-conversion UPS from AC/DC Elektronik: efficiency up to 94%, ±25% input tolerance, input power factor of 0.99 or more and 2 to 3 year warranty.
On this page
Overview
The page presents the AS series 6 kVA and 10 kVA uninterruptible power supplies from the Turkish manufacturer AC/DC Elektronik. The units are true on-line double conversion with a three-level inverter. The maker states efficiency up to 94%, an input voltage tolerance of ±25% and a sinusoidal output. Input power factor is 0.99 or higher, a feature also highlighted for generator compatibility.
The feature list covers protection and monitoring: static and manual bypass, overload, lightning and short-circuit protection, 50/60 Hz automatic frequency detection, smart fan speed control, battery cold start, sleep mode, remote emergency off, automatic battery test and a 128-event power-fault log. An RS-232 port is fitted; SNMP and a remote monitoring panel are optional. A supplementary charger unit extends autonomy and an internal battery option exists.
The page is a product introduction; it carries no load-point efficiency curve and no size or weight table. The manufacturer's related text states that the 6 and 10 kVA models have an output power factor of 1 and are sold with a 2-year warranty including batteries and a 10-year spare-parts guarantee. For a designer the usable data are the rated powers, the efficiency ceiling and the input tolerance.
Key points
- AS series 6 kVA and 10 kVA, single-phase in and out, true on-line double conversion.
- Efficiency up to 94%; input voltage tolerance ±25%.
- Input power factor 0.99 or higher; output power factor 1 (6 and 10 kVA models).
- Three-level inverter, static and manual bypass, generator compatible.
- 128-event log, RS-232 port, optional SNMP and remote monitoring panel.
- Battery cold start, automatic battery test, remote emergency off, sleep mode.
- Warranty: 2 years including batteries, or a 3-year option; 10-year spare-parts guarantee.
Using it in design
- Treat the rated powers (6 and 10 kVA, output PF 1) directly as 6 and 10 kW.
- Note that only an efficiency ceiling (94%) is given; request load-point test values from the maker if an efficiency curve is needed.
- For generator-fed inputs, carry the input PF of 0.99 or more and the ±25% voltage tolerance into the generator sizing notes.
- Write the RS-232, SNMP and dry-contact options explicitly into the monitoring specification.
Who should read it
Electrical designers and suppliers selecting single-phase UPS units for small and medium loads.
Document contents
- AS series 6-10 kVA UPS features
- UPS models (6 kVA, 10 kVA)
- Warranty and service
Publication details
- Authors
- AC/DC Elektronik
- Publisher
- AC/DC Elektronik
- Year
- Year not stated
- Document language
- Turkish
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
AC/DC Elektronik AC/DC AS series 6 kVA and 10 kVA manufacturer product listing. AC/DC Elektronik. https://www.acdc.com.tr/tr/ups_detay2.htm?id=1
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.