BAE SECURA OGiV Block Battery Technical Specification (2023.08)
Original title BAE SECURA OGiV BLOCK technical specification: p.1
BAE Batterien
Technical specification of the BAE SECURA OGiV stationary lead-acid block range: C10, C5, C3 and C1 capacities, dimensions and weights for 12 V (25-150 Ah), 6 V (175-300 Ah) and 2 V (600-900 Ah) units.
On this page
Overview
The document is a two-page table from BAE's August 2023 technical specification of the SECURA OGiV block range. For each type the table gives C10, C5, C3 and C1 capacity at 20 °C, plus length, width, height and filled weight. The end-of-discharge voltage Ue per cell is 1.80 for C10, 1.79 for C5, 1.78 for C3 and 1.74 V for C1. Capacity tolerance is stated as ±5%.
The range comes in three container sizes. 12 V blocks run from 1 OGiV (25 Ah) to 6 OGiV (150 Ah); sizes are 272 x 205 x 385 mm (25-100 Ah) and 380 x 205 x 385 mm (125-150 Ah), weights 35.5 to 81.6 kg. 6 V blocks run from 7 OGiV (175 Ah) to 12 OGiV (300 Ah), 50.8-78.3 kg. 2 V cells are 24 OGiV (600 Ah, 54.9 kg), 30 OGiV (750 Ah, 70.6 kg) and 36 OGiV (900 Ah, 78.3 kg).
The table footnotes refer to blocks with blind cells on request (10, 8, 6, 4 and 2 V in 12 V containers; 4 and 2 V in 6 V containers) and to connection circuits (circuit A for 12 V blocks, circuit B for 6 V blocks). The sheet carries no life, charge-voltage or discharge tables; it gives capacity, size and weight data only.
Key points
- 12 V blocks: 25, 50, 75, 100, 125, 150 Ah (C10); 272 x 205 x 385 mm (25-100 Ah) and 380 x 205 x 385 mm (125-150 Ah).
- 12 V weights: 35.5; 43.0; 50.7; 58.0; 74.1; 81.6 kg.
- 6 V blocks: 175-300 Ah (C10), 50.8-78.3 kg.
- 2 V cells: 600, 750, 900 Ah; 54.9, 70.6, 78.3 kg.
- 12 V 100 Ah: C10 100 Ah, C5 96 Ah, C3 90 Ah, C1 73 Ah.
- End voltage per cell: C10 1.80 V, C5 1.79 V, C3 1.78 V, C1 1.74 V.
- Capacity tolerance ±5%; 20 °C reference.
- Blocks with blind cells on request: 10, 8, 6, 4, 2 V in 12 V containers.
Using it in design
- For a battery string, read capacity at the matching hour rate: use the C1 column for 15-minute backup.
- In rack layout use the 272 or 380 mm length and 205 mm width for 12 V blocks.
- Include filled weight in floor loading; the 150 Ah block weighs 81.6 kg.
- Confirm the connection circuit (A or B) in the battery rack design.
- Refer to the maker's separate documents for life and charge information.
Who should read it
Designers and purchasing engineers sizing lead-acid batteries for UPS and DC power systems.
Document contents
- Type table: capacities C10, C5, C3, C1
- Dimensions and weights
- 12 V, 6 V and 2 V container types
Publication details
- Authors
- BAE Batterien
- Publisher
- BAE Batterien
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
BAE Batterien BAE SECURA OGiV BLOCK technical specification: p.1. BAE Batterien. https://siliconeng.co.za/wp-content/uploads/2025/05/BAE_Technical-Specification_SECURA_OGiV_BLOCK_en_2023.08.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.