Technical guideFree to readYear not stated

C&C Power UBC84 Battery Cabinet: Specifications and Battery Configurations

C&C Power

C&C Power UBC84 battery cabinet mechanical envelope (width, depth, height) and a battery population of up to 30; the installed string and runtime require separate selection.

On this page

Overview

C&C Power's UBC84 battery cabinet product page describes the cabinet's mechanical envelope and the battery population it supports for UPS systems. Cabinet dimensions are listed by width, depth and height; optional features shown on the page are not ratings that apply to every cabinet.

The published maximum supported battery count is 30. This number is a compatibility limit for the cabinet, not the definition of an installed string. The battery model, series and parallel arrangement and backup time to be installed must be calculated separately from the UPS load and battery data.

Key points

  1. The published maximum supported battery count for the UBC84 is 30.
  2. The number is a compatibility limit, not an installed string specification.
  3. Cabinet dimensions are listed by width, depth and height.
  4. Optional features are not universal ratings.

Using it in design

  • Calculate battery count and string arrangement from the UPS DC voltage and target autonomy, using the 30-battery maximum as a boundary condition.
  • Check cabinet dimensions in the UPS room layout together with service clearances.
  • Verify the dimensions and weight of the chosen battery model for cabinet fit and floor loading.
  • State optional equipment separately in the order specification.
  • Treat runtime as a separate selection step.

Who should read it

Electrical designers planning UPS battery strings and cabinet layout.

Publication details

Authors
C&C Power
Publisher
C&C Power
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

C&C Power C&C Power UBC84 Battery Cabinet: Specifications and Battery Configurations. C&C Power. https://www.ccpower.com/products/ubc84-battery-cabinet/

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.