CSPower Battery Catalogue 2023: CH, printed p.20

CSPower

CH high-rate UPS battery table from CSPower's 2023 catalogue: 12 V, 15 models from CH12-35W to CH12-900W, with 15-minute watts per cell and 10-hour Ah ratings.

On this page

Overview

CSPower Battery Tech (Shenzhen) is a battery manufacturer founded in 2003 with about 1000 employees. The 2023 catalogue covers a broad range including VRLA AGM, gel, lead-carbon, OPzV/OPzS, front-terminal, telecom, LiFePO4 and vehicle batteries; the maker lists ISO 9001, ISO 14001, CE, UL and IEC 60896/61427 certificates.

Printed page 20 holds the CH series of high-rate AGM batteries. For each model the table gives nominal voltage (12 V), watts per cell at 15 minutes, Ah at the 10-hour rate, length, width, height, total height, weight (+/-3%), terminal type and bolt size. The series is positioned for small-capacity, high-discharge-current uses such as UPS, EPS, telecom and data centres.

Models: CH12-35W (35 W/cell, 8 Ah, 2.55 kg), CH12-55W (55, 12 Ah), CH12-85W (85, 20 Ah, 6.5 kg), CH12-115W, -145W, -170W, -300W (300 W, 80 Ah, 25 kg), -370W, -420W, -470W, -520W, -680W, -770W, -800W (800 W, 230 Ah, 70 kg) and CH12-900W (900 W, 255 Ah, 79 kg). Length runs from 151 mm to 520 mm; the 10-hour Ah value ranges from 8 to 255.

For UPS battery selection the two capacity values must not be mixed: the watt figure is for a 15-minute discharge, the Ah figure for a 10-hour discharge. The catalogue also shows that the individual CH12-900W data differs in total height between versions, so version-specific drawings should be used for mechanical selection.

Key points

  1. CH series: 12 V, 15 models from CH12-35W to CH12-900W.
  2. Power is given as W per cell for 15 min: 35, 55, 85, 115, 145, 170, 300, 370, 420, 470, 520, 680, 770, 800, 900.
  3. Ah is the 10-hour rate: from 8 to 255 Ah.
  4. CH12-35W 2.55 kg; CH12-300W 25 kg; CH12-900W 79 kg (+/-3%).
  5. CH12-900W measures 520 x 268 x 220 mm, total height 225 mm.
  6. Terminal types F2, T1-T6; bolt sizes M5x16, M6x16 and M8x16.
  7. Gas-recombination design; produces no acid mist.
  8. Uses: telecom, data centre, EPS and UPS, safety and emergency lighting systems.

Using it in design

  • Size the UPS battery string on the 15-minute W/cell rating; do not use the 10-hour Ah rating for autonomy.
  • Match cell count and DC bus voltage to total W/cell and block count against UPS load and efficiency.
  • Carry weight (2.55-79 kg) and dimensions into battery rack and floor-loading calculations.
  • For models whose total height differs between versions (such as CH12-900W) use version-specific mechanical data.
  • Reflect terminal type and bolt size in cable and busbar selection.

Who should read it

Electrical designers sizing UPS battery strings and engineers preparing battery rack layouts.

Document contents

  1. Company profile
  2. Product index
  3. HLC series lead-carbon batteries
  4. CH series high-rate AGM batteries (p.20)
  5. LFP series LiFePO4 batteries

Publication details

Authors
CSPower
Publisher
CSPower
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

CSPower CSPower Battery Catalogue 2023: CH, printed p.20. CSPower. https://www.cspbattery.com/uploads/01-New-CSPower-battery-catalogue-2023.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.