Kung Long IDC/UPS High Rate: Long Life WPL Series Battery Table
Original title Kung Long IDC/UPS High Rate: Long life series
Kung Long Batteries
Kung Long's IDC/UPS long-life WPL table lists 12 V blocks from 4.25 to 195.5 Ah (C10) with dimensions, total height and weight for each model.
On this page
Overview
The page lists the Long life WPL series within the IDC/UPS high-rate battery group of the Taiwanese battery maker Kung Long (KLB). The table has columns for model name, nominal voltage, watt rating, 5, 10 and 20 hour capacity, length, width, height, total height and weight, with a metric or imperial unit switch.
The listed blocks are 12 V. The smallest model is the WPL5-12: C10 4.25 Ah, C20 5 Ah, 90×70×101.5 mm, total height 107 mm, 1.85 kg. The largest is the WPL230-12N: C10 195.5 Ah, C20 230 Ah, 522×238×219 mm, total height 224 mm, 73.1 kg. Models in between spread across 7.2 Ah (WPL7.2-12), 26 Ah (WPL26-12), 40 Ah (WPL40-12), 100 Ah (WPL100-12RN) and 200 Ah (WPL200-12N).
The same capacity has several variants: for example WPL26-12 appears as 12N, 12B and 12NB, and WPL200-12 with the SN, BN and N suffixes; they differ in physical details such as height, total height or weight (WPL200-12SN 58.5 kg, WPL200-12N 68 kg). The model suffix should therefore be read as a separate parameter for rack layout and load calculation.
The document is at block level. Battery cabinet energy, load-time relationship or design life is not given in this table; it contains only the identity, capacity and dimensions of a single battery. Total height (HT) in the table is the height including terminals and differs between variants on some models (for example WPL55-12, 207 mm height, 214/229 mm total).
Key points
- WPL long-life series; 12 V blocks, IDC/UPS high-rate group.
- Smallest model: WPL5-12, C10 4.25 Ah, C20 5 Ah, 1.85 kg.
- Largest model: WPL230-12N, C10 195.5 Ah, C20 230 Ah, 522×238×219 mm, 73.1 kg.
- Capacity examples: WPL26-12 26 Ah (8-8.8 kg), WPL100-12RN 100 Ah (31.3 kg), WPL200-12N 200 Ah (68 kg).
- The same capacity has several variants (for example WPL26-12, 26-12N, 26-12B, 26-12NB).
- Weight differences between variants: WPL200-12SN 58.5 kg, 12BN 61 kg, 12N 68 kg.
- The table gives length, width, height and total height including terminals (HT).
- Capacity is presented in 5, 10 and 20 hour columns.
Using it in design
- Read the model suffix (N, B, RN, SN and so on) as a physical and weight difference and check it separately in rack or cabinet layout.
- Use total height (HT) for rack placement; leave clearance for terminals and connections.
- Compare capacity on a C10 or C20 basis; the manufacturer lists C10 at about 85% of C20.
- Compare block weights (1.85-73.1 kg) with rack load limits and manual-handling rules.
- Calculate cabinet energy yourself from block count and voltage; the table does not give it.
Who should read it
Electrical designers sizing data-centre UPS battery banks, and engineers preparing battery rack layouts.
Document contents
- Product list: Long life series (IDC/UPS high rate)
- Table columns: model, nominal voltage, capacity (5/10/20 hour), dimensions, weight
- Metric and imperial unit switch
Publication details
- Authors
- Kung Long Batteries
- Publisher
- Kung Long Batteries
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Kung Long Batteries Kung Long IDC/UPS High Rate: Long life series. Kung Long Batteries. https://www.kunglong.com/solution/IDC-UPS-high-rate/IDC-UPS-high-rate-long-life-series/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.