Mutlu Industrial Stationary OPzS Catalogue: 2022_05, printed pp.14-15

Original title Mutlu Industrial Stationary OPzS Catalogue: 2022_05, printed pp.14–15

Mutlu Akü

Mutlu Akü's monobloc OPzS data list gives 10-hour discharge current, voltage and the maximum mechanical envelope; the maximum mass is not an exact mass rating.

On this page

Overview

Mutlu Akü's industrial stationary OPzS catalogue (edition 2022_05) gives a data list for monobloc OPzS batteries on printed pages 14 and 15. For each model the list holds the 10-hour discharge current, the voltage and the maximum mechanical envelope (dimensions).

The maximum mass in the list is not an exact mass value; it is given as an upper bound. The pages therefore serve to determine current, voltage and footprint in battery selection, and an exact mass should be requested from the manufacturer for floor-loading calculations.

Key points

  1. The source is the Mutlu Akü industrial stationary OPzS catalogue (2022_05, printed pp.14-15).
  2. The data list covers monobloc OPzS batteries.
  3. The 10-hour discharge current is given for each model.
  4. Voltage is listed per model.
  5. The maximum mechanical envelope (dimensions) is given.
  6. The maximum mass is not an exact mass rating.

Using it in design

  • Size the battery string against the 10-hour discharge current and match model voltage to the UPS DC bus voltage.
  • Use the maximum mechanical envelope in rack and room layout.
  • Take the maximum mass as an upper bound in floor-loading calculations and confirm the exact mass with the manufacturer.
  • Request the manufacturer's discharge tables separately for autonomy time.

Who should read it

Electrical engineers designing stationary battery systems and battery rooms.

Publication details

Authors
Mutlu Akü
Publisher
Mutlu Akü
Year
Year not stated
Document language
Unverified
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Mutlu Akü Mutlu Industrial Stationary OPzS Catalogue: 2022_05, printed pp.14–15. Mutlu Akü. https://cdnd.mutlu.com.tr/sector/katalog/626545618066a30dde48040398860a13f8eec8c2.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.