Technical guideFree to readYear not stated

Falcon FN2 4.5-10 kVA datasheet, p.2 rackmount table (image checked)

Original title Falcon FN2 4.5–10 kVA datasheet, p.2 rackmount table (image checked)

Falcon Electric

Falcon Electric's FN2 rackmount: 4.5, 6, 8 and 10 kVA at unity output power factor, 240 Vdc battery, 0 ms transfer, 90-91% normal and 94-95% ECO efficiency, N+1 paralleling to 40 kVA.

On this page

Overview

Falcon Electric's FN2 datasheet presents a DSP-controlled true on-line UPS family with unity power factor. The rackmount table on page 2 covers four models: FN2-4.5KRM-2TXI, FN2-6KRM-2TXI, FN2-8KRM-2TXI and FN2-10KRM-2TXI. Output power is 4500, 6000, 8000 and 10000 W (power factor 1). The family supports 3+1 parallel redundancy and up to four units in parallel, that is scaling to 40 kVA; a PDU with or without a maintenance bypass switch is offered as an option.

On the electrical input, nominal voltage is 208 or 240 Vac, frequency range 45-70 Hz, input power factor 0.99 at full linear load and input harmonic distortion 5% or less. The input voltage range depends on load: 176-280 V at 100% load, 160-176 V below 75% load and 110-160 V below 50% load. Input current is 30, 36, 52 and 62 A by model. Efficiency is 90% (normal) and 94% (ECO) for 4.5 and 6 kVA, and 91% and 95% for 8 and 10 kVA.

On the output, voltage is 120/208, 110/220, 115/230 or 120/240 Vac (isolated output), regulation +/-3%, harmonic distortion 3% or less and crest factor 3:1. Overload capability is 480 seconds at 110%, 30 seconds at 125% and immediate at 150%. The battery system is 240 Vdc, user-replaceable, five hot-swappable packs of 12 Vdc/9 Ah maintenance-free VRLA. Full-load/half-load runtime is 9.5/26 min for 4.5 kVA, 5.5/17 min for 6 kVA, 4/11.5 min for 8 kVA and 2/8.5 min for 10 kVA.

Physical data: the UPS inverter is 2U (88 x 440 x 680 mm) and the transformer and battery bank are 3U (132 x 440 x 665 mm); system weight is 114.5 kg for 4.5 and 6 kVA and 142.5 kg for 8 and 10 kVA. Operating temperature is 0 to 40 C, humidity 20-95% non-condensing, altitude 1000 m and noise under 60 dBA; heat dissipation is 2559, 3412, 4095 and 4777 BTU/hr. Approvals are UL1778, cUL, FCC Class A and CE. The table covers only the rackmount columns; tower model codes are separate.

Key points

  1. Four models: 4.5, 6, 8 and 10 kVA; output 4500, 6000, 8000, 10000 W; output power factor 1.
  2. Efficiency: 4.5 and 6 kVA are 90% normal and 94% ECO; 8 and 10 kVA are 91% normal and 95% ECO; input current is 30, 36, 52, 62 A.
  3. Input is 208 or 240 Vac, 45-70 Hz; input power factor 0.99 and THDi 5% or less; input range is 176-280 V at 100% load.
  4. Output regulation is +/-3%, THD 3% or less, crest factor 3:1; overload 110%/480 s, 125%/30 s, 150% immediate.
  5. Battery is 240 Vdc; five hot-swappable packs; 12 Vdc/9 Ah VRLA; charge current 1.7 A; recharge to 90% in 6 hours.
  6. Runtime (full/half load): 4.5 kVA 9.5/26 min; 6 kVA 5.5/17 min; 8 kVA 4/11.5 min; 10 kVA 2/8.5 min.
  7. Transfer time is 0 ms (line fail, bypass); parallel capacity 4 units (up to 40 kVA), 3+1 redundancy.
  8. System weight is 114.5 kg (4.5 and 6 kVA) and 142.5 kg (8 and 10 kVA); heat dissipation 2559-4777 BTU/hr; noise under 60 dBA.

Using it in design

  • Size capacity from output power (power factor 1); the 10 kVA model carries 10 kW.
  • Read runtime from the table for full and half load; at 10 kVA full load it is only 2 min, so longer runtime needs the extended battery banks.
  • Use the input current (30-62 A) and the load-dependent lower input limits in supply design.
  • Put the 3+1 parallel structure and the 4-unit limit (40 kVA) into the capacity plan for N+1.
  • Add the heat dissipation (2559-4777 BTU/hr) and the 40 C operating limit to the cooling load calculation; weigh ECO-mode efficiency against its protection level.

Who should read it

Electrical designers and IT infrastructure managers seeking N+1 UPS for small and mid-size rack loads.

Document contents

  1. Overview and key advantages
  2. Rackmount model table: electrical input and output, battery, transfer time, connections, environment, controls, mechanical, approvals

Publication details

Authors
Falcon Electric
Publisher
Falcon Electric
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Falcon Electric Falcon FN2 4.5–10 kVA datasheet, p.2 rackmount table (image checked). Falcon Electric. https://falconups.com/wp-content/uploads/16-FN2-4.5-10kVA-Online-UPS-Rackmount-Tower.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.