KUTAI BTB Programmable Automatic Transfer Switch (ATS)
Original title KUTAI Programmable Automatic Transfer Switch BTB
KUTAI
KUTAI's BTB brochure defines 100, 250 and 400 A MCCB-type automatic transfer switches with an integrated controller, IEC 60947-6-1 compliance and timers adjustable up to 999 seconds.
On this page
Overview
The brochure introduces the BTB series of programmable automatic transfer switches (ATS) from the Taiwanese manufacturer KUTAI. The series integrates the controller and the MCCB into one product, saving space, installation time and cost. Rated currents are 100 A and 250 A for 2P, 3P and 4P, and 400 A for 2P only. The device complies with IEC 60947-6-1 and utilisation category AC-33A.
The device comes in two classes: Class CB provides overcurrent protection and its main contacts can make and break short-circuit current; Class PC withstands short-circuit current but cannot break it. CB-class MCCBs have a rated insulation voltage of 690 V; for 100/250 A and 400 A, breaking capacity (Icu/Ics) is 50/25 kA at 220/240 V, 30/15 kA at 380/415 V, 25/13 kA at 440 V and 20/10 kA at 550 V. Electrical and manual operation, terminal-lug connections, a safety lock to protect personnel during maintenance, and mechanical and electrical interlocking are provided.
The controller monitors and protects all phase voltage and frequency for utility and generator. Settings are entered on a colour LCD. Adjustable timers: emergency-to-normal delay (TDEN) 0-999 s, normal-to-emergency (TDNE) 0-250 s, engine start (TDES) 0-15 s, engine cool-down (TDEC) 0-250 s and OFF-position delay (TDOF) 0-99 s; the weekly exercise timer is adjustable from 1 to 4 weeks. The remote engine-start output is 7 A at 250 Vac and the auxiliary output 3 A.
Physical data: 2P/3P 225×293×170 mm, 4P 225×293×205 mm (L×W×H); weight 2P250A 5.1 kg, 3P250A 5.6 kg, 4P250A 6.8 kg, 2P400A 7.0 kg (±2%). Operating temperature is -20 to +60 °C, storage -30 to +80 °C and relative humidity at most 90%. The model code specifies distribution system (1P/3W, 1P/2W, 3P/3W, 3P/4W), current, certification, voltage and enclosure (none, indoor, outdoor). A CTM-25 current transformer and communication module are optional for smartphone remote monitoring.
Key points
- Rated current: 100 A and 250 A for 2P/3P/4P; 400 A for 2P only.
- Integrated programmable controller and MCCB; IEC 60947-6-1 and category AC-33A.
- Class CB (overcurrent protection, can break short circuit) and Class PC (withstands short circuit, cannot break).
- CB-class breaking capacity Icu/Ics: 220/240 V 50/25 kA; 380/415 V 30/15 kA; 440 V 25/13 kA; 550 V 20/10 kA.
- Timers: TDEN 0-999 s, TDNE 0-250 s, TDES 0-15 s, TDEC 0-250 s, TDOF 0-99 s; weekly exercise 1-4 weeks.
- All-phase voltage/frequency monitoring and protection for utility and generator; mechanical and electrical interlocks.
- Generator start output 7 A @ 250 Vac, auxiliary output 3 A @ 250 Vac.
- Operating temperature -20 to +60 °C; size 225×293×170 mm (2P/3P) and 205 mm height (4P); weight 5.1-7.0 kg.
- Options: CTM-25 current transformer and communication module, enclosure (indoor/outdoor), four display languages.
Using it in design
- Coordinate generator start-up time with the TDES, TDEN and TDNE timer settings; the return-transfer delay can be set up to 999 seconds.
- Choose Class CB if short-circuit breaking is needed and Class PC only if withstand is enough, and compare fault current with the breaking capacity.
- For a 400 A load, confirm from the model note that a 4P MCCB is connected as 2P.
- Put the weekly exercise timer into the generator test regime.
- If remote monitoring is needed, write the CTM-25 and communication module into the specification.
Who should read it
Electrical engineers designing generator and utility changeover and selecting ATS for small and mid-size backup power systems.
Document contents
- Features
- MCCB rated current and rated breaking capacity (Class CB only)
- Specifications and adjustable timer settings
- Model number description
- Dimensions and physical specifications
- Environment
Publication details
- Authors
- KUTAI
- Publisher
- KUTAI
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
KUTAI KUTAI Programmable Automatic Transfer Switch BTB. KUTAI. https://www.kutai.com.tw/download/btb-type-ats/btb-type-ats-brochure-en.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.
