Microtek i-MAXX Series Online UPS Brochure

Original title Microtek i-MAXX series brochure, p.3 3-phase input/output table

Microtek

Microtek i-MAXX is an online UPS family with built-in isolation transformers, DSP control and IGBT inverters, offered as 5.5 to 10 kVA single-phase, 10 to 20 kVA 3-in/1-out and 10 to 30 kVA 3-in/3-out models.

On this page

Overview

The Microtek i-MAXX series is an online UPS family built on DSP technology with an IGBT-based inverter and built-in isolation transformers. The brochure presents three groups: 5.5, 7.5 and 10 kVA models (16/18 battery system), 10, 15 and 20 kVA models with three-phase input and single-phase output, and 10, 20 and 30 kVA models with three-phase input and three-phase output. All include a built-in maintenance bypass and a static bypass switch.

Shared features are over-voltage cut-off with surge protection, constant voltage constant frequency (CVCF) operation without a battery, an EMI/RFI filter, conformal-coated boards, pure sine wave in battery mode and zero transfer time from AC to DC and from inverter to bypass. The manufacturer states the UPS is generator compatible and that the generator capacity for the standby source should be 2.5 times the UPS capacity.

The 360 V models add a 20 A built-in charger, parallel redundancy and battery reverse protection; on three-phase output models the battery count is settable at 29, 30, 31 or 32. Output frequency can be fixed at 50 Hz or synchronised to input, and the units tolerate reverse phase sequence and no-neutral operation. RS-232, USB and RS-485 ports are provided with an optional SNMP card. The technical tables in the brochure are images, so the text carries only the feature lists.

Key points

  1. Three groups: 5.5 / 7.5 / 10 kVA; 10 / 15 / 20 kVA (3-in, 1-out); 10 / 20 / 30 kVA (3-in, 3-out).
  2. Built-in isolation transformer, DSP control, IGBT inverter, built-in maintenance bypass and static bypass.
  3. Generator compatibility: generator capacity should be 2.5 times the UPS capacity.
  4. Transfer time is zero for AC to DC and inverter to bypass.
  5. 360 V models: 20 A built-in charger, parallel redundancy and battery reverse protection.
  6. On 3-phase output 360 V models the battery count is settable at 29, 30, 31 or 32.
  7. External charger capacity expansion up to 4 A (optional).
  8. Output frequency fixed at 50 Hz or synchronised to input; RS-232, USB, RS-485 and optional SNMP.

Using it in design

  • At generator-backed sites, size the generator at 2.5 times the UPS capacity.
  • The transformer-based design helps where galvanic isolation at the output or harsh mains is needed; include transformer losses in efficiency calculations.
  • On a 360 V battery string, match the 29 to 32 battery count to the battery maker's float voltage.
  • If parallel redundancy is needed, specify the 360 V model and its parallel kit.
  • Request the manufacturer's full table page for detailed values, since dimensions and efficiencies are in an image table.

Who should read it

Electrical engineers looking for transformer-based, industrial-type UPS units and assessing generator compatibility.

Document contents

  1. 5.5 / 7.5 / 10 kVA online UPS models
  2. 10 / 15 / 20 kVA online UPS models (3-phase in, 1-phase out)
  3. 10 / 20 / 30 kVA online UPS models (3-phase in, 3-phase out)

Publication details

Authors
Microtek
Publisher
Microtek
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Microtek Microtek i-MAXX series brochure, p.3 3-phase input/output table. Microtek. https://cms.microtek.in/upload/product_series/imax-1721388791523.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.