Prostar Jupiter Series High Frequency Online UPS 10-80 kVA (3/3, PF 1.0)
Original title Prostar Jupiter PHT33 10–80 kVA technical specifications
Prostar
Prostar Jupiter is a 10-80 kVA three-phase high-frequency online UPS with 1.0 output power factor, 96% efficiency in AC and battery modes, 99% in ECO mode, silicon carbide diodes and parallel operation of up to 6 units.
On this page
Overview
The page presents the Prostar Jupiter models PHT3310, 3320, 3330, 3340, 3360 and 3380 (10, 20, 30, 40, 60 and 80 kVA, kVA = kW). The series combines DSP and MCU dual-chip architecture for reliability, dual input, parallel operation of up to 6 units, a 5-inch colour touch LCD, a programmable relay card, voice warnings, a dynamic password and power walk-in for generator optimisation. Silicon carbide diodes give efficiency above 96% in all modes.
Electrical data: input 380/400/415 V AC (3Ph+N+PE), voltage range -30% to +20%, 40-70 Hz, power factor at least 0.99, THDi below 3% at full linear load. Output regulation is ±1% in battery mode, crest ratio 3:1, THD at most 1% on linear and 3% on non-linear load; transfer from AC to battery and from inverter to bypass is zero. Overload is 60 min at 100-110%, 10 min at 111-125%, 1 min at 126-150% and 400 ms above 150%. Efficiency is 96% in AC mode, 99% in ECO mode and 96% in battery mode.
Battery voltage is ±120 V for the 10 kVA (12 V x10) and selectable ±192 to ±240 V DC (12 V x16-20) for the others; maximum charging current is 12 A, 16 A, 24 A and 32 A by model. Dimensions (D x W x H) are 630x250x826 mm (28 kg) to 790x360x1010 mm (113 kg); the environment is 0-40 °C, humidity below 95%, altitude 0-1500 m at full load, noise 60-65 dB at 1 m. Management is by RS-232/USB with optional SNMP.
Key points
- Six models: PHT3310, 3320, 3330, 3340, 3360, 3380 = 10/20/30/40/60/80 kVA (kVA = kW).
- Output power factor 1.0; input power factor at least 0.99; input THDi below 3%.
- Efficiency: 96% AC mode, 99% ECO mode, 96% battery mode.
- Input 380/400/415 V AC, -30% / +20%; frequency 40-70 Hz.
- Overload: 60 min at 100-110%, 10 min at 111-125%, 1 min at 126-150%, 400 ms above 150%.
- Battery: ±120 V for 10 kVA (12 V x10); others ±192 to ±240 V DC (12 V x16-20); maximum charge current 12-32 A.
- Parallel operation up to 6 units; dual input; 5-inch colour touch LCD.
- Size 630x250x826 mm (28 kg) to 790x360x1010 mm (113 kg); 0-40 °C; altitude 1500 m; noise 60-65 dB.
Using it in design
- With 1.0 power factor, compare kVA directly with the kW load list.
- Match the battery bus voltage (±120 V or ±192-240 V) to the external battery cabinet and the chosen block count.
- Record the 6-unit parallel limit in the redundancy capacity plan.
- On generator-fed sites, evaluate power walk-in together with generator sizing and load steps.
- Carry the 1500 m altitude limit and 0-40 °C range into the layout decision.
Who should read it
Electrical designers selecting mid-power three-phase high-efficiency UPS.
Document contents
- Product Description
- Features Introduction
- Technical Specification
- Applied Range
- Product Catalogue
Publication details
- Authors
- Prostar
- Publisher
- Prostar
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Prostar Prostar Jupiter PHT33 10–80 kVA technical specifications. Prostar. https://www.prostarpower.com/jupiter_series_high_frequency_online_ups_10kva-80kva_3/3_phase.html
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.