DC-UPS with Ethernet: Adelsystem CBI60W and CBI600W Series
Original title AdelSystem DC UPS with Ethernet
AdelSystem
The Adelsystem CBI60W/CBI600W series are all-in-one DC-UPS modules up to 600 W and 56 V with built-in Ethernet (SNMPv3, Modbus TCP/IP, HTTPS) and a web server, in 12, 24 and 48 V models.
On this page
Overview
The product page introduces Adelsystem's DC-UPS family with an Ethernet interface. The series offers up to 600 W and output voltage up to 56 V. Models are CBI6012A (12 V, 5 A), CBI6024A (24 V, 2.5 A), CBI6048A (48 V, 1.25 A), CBI60024A (24 V, 25 A) and CBI60048A (48 V, 12.5 A), with 110-240-277 Vac input. Power supply, battery charger and backup module functions are combined in one module.
The Ethernet interface supports SNMPv3, Modbus TCP/IP and HTTPS and gives access through an internal web server with its own IP address. Monitored parameters include AC input voltage, DC output voltage, current, power and status, battery voltage, current and internal resistance, and network, device and battery faults. Logging, configuration and alarm notification are possible, aimed at SCADA or IoT integration.
Battery care uses Adelsystem's Battery Care technology: battery-specific charge profiles for lead acid, AGM, gel, NiCd, NiMH, Li-Ion and LiFePO4, temperature compensation, deep discharge protection, charge current limiting and a battery test (connection, reverse polarity, shorted cells, internal impedance). The load output can be switched by web command or external button, enabled when the AC grid fails, run for a set time or cycled, and the relay contacts are configurable.
Key points
- Power up to 600 W, output up to 56 V; 12, 24 and 48 V models.
- Models: CBI6012A 12 V 5 A, CBI6024A 24 V 2.5 A, CBI6048A 48 V 1.25 A, CBI60024A 24 V 25 A, CBI60048A 48 V 12.5 A.
- Input 110-240-277 Vac.
- Built-in Ethernet: SNMPv3, Modbus TCP/IP, HTTPS and web server.
- Monitored values: AC input voltage, DC output voltage/current/power, battery voltage/current/internal resistance.
- Battery types: lead acid, AGM, gel, NiCd, NiMH, Li-Ion, LiFePO4.
- Configurable load output (timed, cyclic, on grid failure) and configurable fault, AC grid and rectifier fault relays.
Using it in design
- Plan to connect DC backup modules in telecom, security and control applications to the BMS over SNMPv3 or Modbus TCP/IP.
- Verify the charge profile and temperature compensation for the chosen battery type before commissioning.
- Use battery internal resistance and health data as maintenance alarm thresholds.
- Limit load to the 600 W ceiling and the model's current rating; larger loads need paralleling or a different series.
Who should read it
Designers seeking monitorable backup power for surveillance, access control and small DC loads around a data centre.
Document contents
- DC-UPS with Ethernet
- Battery Care technology
- Ethernet integration and monitored parameters
- Internal webserver
- Load output and relay configuration
- Datasheets and manuals by model
Publication details
- Authors
- AdelSystem
- Publisher
- AdelSystem
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
AdelSystem AdelSystem DC UPS with Ethernet. AdelSystem. https://adelsystem.com/en/dcups/dc-ups-with-ethernet
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.