SIEL Safepower EVO HF 10-200 kVA UPS brochure and technical table
Original title SIEL Safepower Evo HF BR076 Rev.02, technical table p.2
SIEL
SIEL Safepower EVO HF, a 10-200 kVA double-conversion on-line UPS: VFI-SS-111, up to 96.6% on-line efficiency, 99% in ECO mode, input THDI at most 3%.
On this page
Overview
The brochure (BR076 REV.02) presents SIEL's Safepower EVO HF series and its technical table. The series is a double-conversion on-line UPS in ten sizes (10, 20, 30, 40, 60, 80, 100, 120, 160 and 200 kVA), classified VFI-SS-111 under IEC EN 62040-3. Output power factor is 1, and it supplies inductive and capacitive loads alike.
Total efficiency reaches up to 96.6% in on-line mode and up to 99% in ECO mode. Input current distortion THDI is at most 3% and the input power factor at full load is 0.99. The input is 380/400/415 V three-phase plus neutral at 50/60 Hz, and the output voltage is selectable in the same range.
Output static/dynamic stability is +/-1% and below 5%, with recovery to +/-1% within 20 ms under EN 62040-3 Class 1; THDV is at most 1% on linear and 1.5% on non-linear load. Overload limits are 110% for 60 min, 125% for 10 min, 150% for 1 min, 200% for 0.5 s and 0.2 s above that. The battery is standard VRLA with optional LiFePO4, as 20+20 blocks of 12 V with a centre-point neutral.
Up to 8 units can be paralleled. The series meets EN 50171 and offers cold start, a configurable frequency-converter mode, a multilingual HMI, and monitoring through SNMP, RS232 and RS485 Modbus. The 10-60 kVA models can hold batteries inside the cabinet. Protection is IP20 (IP21/IP31 optional), operating temperature 0-40 °C and humidity 0-95% non-condensing.
Key points
- Ten sizes from 10 to 200 kVA; output power factor 1.
- Class VFI-SS-111 (IEC EN 62040-3), dynamic Class 1.
- Efficiency: up to 96.6% on-line, up to 99% in ECO mode.
- Input THDI at most 3%; input power factor 0.99.
- Overload: 110% for 60 min, 125% for 10 min, 150% for 1 min, 200% for 0.5 s.
- Up to 8 units in parallel; EN 50171 compliant; cold start.
- Dimensions from 440x840x1320 mm (10-20 kVA) to 840x1050x1900 mm (larger models).
- Battery: standard VRLA, optional LiFePO4; 20+20 blocks of 12 V.
Using it in design
- Compare the design load directly in kVA = kW (PF 1) and check that peaks stay within the 110%, 125% and 150% overload limits.
- Before counting on ECO-mode efficiency, check that the VFI class drops in that mode and whether the load tolerates it.
- Settle the battery block count (20+20 x 12 V), charge-current limit and the LiFePO4 option together with the UPS data sheet.
- For N+1, carry the 8-unit parallel limit into the cable and distribution plan.
- Verify footprints such as 840x1050x1900 mm and that IP20 protection suits the electrical room.
Who should read it
Electrical designers selecting medium and large UPS for data centres and critical facilities, and engineers writing specifications.
Document contents
- Safepower Evo HF overview and features
- Technical data: dimensions and weights
- Input and battery data
- Output data and overload
- General data and standards
Publication details
- Authors
- SIEL
- Publisher
- SIEL
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
SIEL SIEL Safepower Evo HF BR076 Rev.02, technical table p.2. SIEL. https://sielups.com/wp-content/uploads/2024/06/BR076-REV02-BROCHURE-FLYER-SAFEPOWER-EVO-HF.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.