Wöhrle WISUS-MH modular 3-phase UPS product page
Original title Wöhrle WISUS-MH manufacturer product page
Wöhrle
Wöhrle WISUS-MH is a double-conversion, plug-in modular 3-phase UPS with 100 kW modules, 600, 800, 1200 and 1600 kW cabinets, efficiency up to 97% and up to 4.8 MW in parallel.
On this page
Overview
The product page from Wöhrle Stromversorgungssysteme GmbH (Steinenbronn, Germany) presents the WISUS-MH series as a plug-in modular 3-phase UPS using double-conversion technology. The heading gives a 100-1200 kVA range and 97% energy efficiency, while the product highlights give cabinet powers of 400-1600 kW that can be paralleled. The document is a manufacturer promotion page rather than a technical table; detailed technical information is requested through a contact form.
On power density, the 100 kW power modules deliver 750 kW per square metre in a compact 600 kW cabinet with a footprint of 0.8 x 1 m. The page says this density saves about 50% of installation space. The portfolio includes system cabinets of 600, 800, 1200 and 1600 kW.
For scalability, up to four units can be paralleled (two at 1600 kW) to reach a maximum 4.8 MW output. Efficiency in normal operation is up to 97%; an intelligent ECO mode minimises energy losses, and hibernation technology removes the negative effects of the low-load range even in online double-conversion mode. Power loss is given as below 1%.
For reliability the power, bypass and control modules are hot-swappable and the design is redundant; real-time monitoring lowers maintenance cost. The page gives efficiency and power figures with no load point or test condition.
Key points
- Double-conversion plug-in modular 3-phase UPS; heading 100-1200 kVA, highlights 400-1600 kW.
- 100 kW power modules; system cabinets of 600, 800, 1200 and 1600 kW.
- 600 kW cabinet: footprint 0.8 x 1 m, power density 750 kW per square metre; about 50% installation space saving.
- Up to four units in parallel (two at 1600 kW); maximum 4.8 MW.
- Efficiency up to 97%; power loss below 1%; intelligent ECO mode and hibernation.
- Power, bypass and control modules are hot-swappable; real-time monitoring.
Using it in design
- In a modular UPS architecture, divide the 100 kW module step against N+1 redundancy and growth planning; take cabinet powers (600-1600 kW) from the page.
- Use the 750 kW per square metre density in electrical room area calculations; the 0.8 x 1 m footprint excludes service clearances.
- Since the 97% efficiency has no load point, request a load-point efficiency curve from the manufacturer before using it as a design input.
- Assess the efficiency gain from hibernation and ECO mode together with load protection requirements.
- Have the manufacturer confirm the kVA in the heading and the kW in the highlights in a single rating table.
Who should read it
Power designers selecting modular UPS for large data centres.
Document contents
- Product highlights
- Intelligent technology
- Maximum power density
- Scalability
- High energy efficiency
- Reliable and user-friendly
Publication details
- Authors
- Wöhrle
- Publisher
- Wöhrle
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Wöhrle Wöhrle WISUS-MH manufacturer product page. Wöhrle. https://woehrle-svs.de/en/products-2/wisus-mh
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.