Wöhrle WISUS-MH modular 3-phase UPS product page

Original title Wöhrle WISUS-MH manufacturer product page

Wöhrle

Wöhrle WISUS-MH is a double-conversion, plug-in modular 3-phase UPS with 100 kW modules, 600, 800, 1200 and 1600 kW cabinets, efficiency up to 97% and up to 4.8 MW in parallel.

On this page

Overview

The product page from Wöhrle Stromversorgungssysteme GmbH (Steinenbronn, Germany) presents the WISUS-MH series as a plug-in modular 3-phase UPS using double-conversion technology. The heading gives a 100-1200 kVA range and 97% energy efficiency, while the product highlights give cabinet powers of 400-1600 kW that can be paralleled. The document is a manufacturer promotion page rather than a technical table; detailed technical information is requested through a contact form.

On power density, the 100 kW power modules deliver 750 kW per square metre in a compact 600 kW cabinet with a footprint of 0.8 x 1 m. The page says this density saves about 50% of installation space. The portfolio includes system cabinets of 600, 800, 1200 and 1600 kW.

For scalability, up to four units can be paralleled (two at 1600 kW) to reach a maximum 4.8 MW output. Efficiency in normal operation is up to 97%; an intelligent ECO mode minimises energy losses, and hibernation technology removes the negative effects of the low-load range even in online double-conversion mode. Power loss is given as below 1%.

For reliability the power, bypass and control modules are hot-swappable and the design is redundant; real-time monitoring lowers maintenance cost. The page gives efficiency and power figures with no load point or test condition.

Key points

  1. Double-conversion plug-in modular 3-phase UPS; heading 100-1200 kVA, highlights 400-1600 kW.
  2. 100 kW power modules; system cabinets of 600, 800, 1200 and 1600 kW.
  3. 600 kW cabinet: footprint 0.8 x 1 m, power density 750 kW per square metre; about 50% installation space saving.
  4. Up to four units in parallel (two at 1600 kW); maximum 4.8 MW.
  5. Efficiency up to 97%; power loss below 1%; intelligent ECO mode and hibernation.
  6. Power, bypass and control modules are hot-swappable; real-time monitoring.

Using it in design

  • In a modular UPS architecture, divide the 100 kW module step against N+1 redundancy and growth planning; take cabinet powers (600-1600 kW) from the page.
  • Use the 750 kW per square metre density in electrical room area calculations; the 0.8 x 1 m footprint excludes service clearances.
  • Since the 97% efficiency has no load point, request a load-point efficiency curve from the manufacturer before using it as a design input.
  • Assess the efficiency gain from hibernation and ECO mode together with load protection requirements.
  • Have the manufacturer confirm the kVA in the heading and the kW in the highlights in a single rating table.

Who should read it

Power designers selecting modular UPS for large data centres.

Document contents

  1. Product highlights
  2. Intelligent technology
  3. Maximum power density
  4. Scalability
  5. High energy efficiency
  6. Reliable and user-friendly

Publication details

Authors
Wöhrle
Publisher
Wöhrle
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Wöhrle Wöhrle WISUS-MH manufacturer product page. Wöhrle. https://woehrle-svs.de/en/products-2/wisus-mh

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.