Xtreme Power P91g is a 208/230 VAC online UPS in four models from 1000 to 3000 VA, with 98% efficiency in ECO mode, 94% in online mode and up to 8 external battery packs.

On this page

Overview

The flyer from Xtreme Power Conversion Corporation (Denver, USA) presents the P91g series as a lead-acid battery, 208/230 VAC online UPS. There are four models: P91gc-1000 (1000 VA / 800 W), P91g-1500 (1500 VA / 1500 W), P91g-2000 (2000 VA / 2000 W) and P91g-3000 (3000 VA / 3000 W). Tower, wall, 2-post and 4-post rack mounting are possible and the battery is hot-swappable. The document is rev. 15 Sept 2026.

Input is 208/220/230/240 VAC, 50/60 Hz auto-sensing; output is nominal 230 VAC (200/208/220/230/240 selectable on 1500 VA and above, with capacity derated to 90% at 208 V). The waveform is pure sine; THD is 3% (linear) and 5% (non-linear) on 1U and 2% and 4% on 2U. Efficiency reaches up to 98% in ECO mode and 94% in online mode. Overload capacity in 1U online mode is 105-130% for 2 minutes, 130-200% for 10 seconds and above 200% for 250 ms; for 2U it is 110-130% for 5 minutes, 130-140% for 30 seconds and above 140% for 1.5 seconds.

The batteries are sealed maintenance-free lead acid: 4 x 6 V for the P91gc-1000 and 3, 4 and 6 pieces of 12 V / 9 Ah for the 1500, 2000 and 3000. Charging current is adjustable (1/2/4/6/8/12 A); default 2 A, at most 12 A on 1500 and 2000 VA and 8 A on 3000 VA. External packs extend it up to 8 packs; for the P91g-1500 (BP36) 42/17 minutes at 50%/100% load with one pack and 339/146 minutes with eight. The optional XBDM maintenance bypass allows the unit to be replaced without interrupting the load.

Width is 437 mm: P91gc-1000 is 437 x 452 x 43 mm and 12.7 kg; P91g-1500 437 x 384 x 89 mm and 15.5 kg; P91g-2000 437 x 482 x 89 mm and 19.5 kg; P91g-3000 437 x 605 x 89 mm and 27.5 kg. Operation is 0-40 °C up to 1980 m; approvals are CE, RoHS and TAA; warranty is 3 years electronics and 3 years battery (USA and Canada).

Key points

  1. Models: P91gc-1000 (1000 VA/800 W), P91g-1500 (1500 VA/1500 W), P91g-2000 (2000 VA/2000 W), P91g-3000 (3000 VA/3000 W).
  2. Input 208/220/230/240 VAC, 50/60 Hz auto; output 230 VAC (200-240 selectable); 90% power at 208 V.
  3. Efficiency: up to 98% in ECO mode, up to 94% in online mode.
  4. THD: 3% (linear) and 5% (non-linear) on 1U; 2% and 4% on 2U.
  5. Battery: 4 x 6 V (1000 VA), 3 x 12 V/9 Ah (1500), 4 x (2000), 6 x (3000).
  6. Up to 8 external battery packs; P91g-1500 (BP36) 42/17 min with 1 pack, 339/146 min with 8 packs (50%/100% load).
  7. Weight 12.7 kg (1000 VA), 15.5 kg (1500), 19.5 kg (2000), 27.5 kg (3000).
  8. Operation 0-40 °C up to 1980 m; warranty 3 years electronics and 3 years battery.

Using it in design

  • For small critical loads take kW per model: the 1000 VA model is 800 W, the 1500-3000 VA models have unity power factor.
  • Separate efficiency in the energy budget as online (94%) and ECO (98%); ECO mode protection differs from double conversion, so judge it against load sensitivity.
  • For autonomy choose the number of external battery packs from the runtime table; there is a limit of 8 packs (excluding the P91g-1500 BP36E).
  • If maintenance bypass is needed, order the XBDM option; allow for the 90% derating at 208 V output.
  • For sites above 1980 m ask the manufacturer for derating.

Who should read it

Designers and IT infrastructure teams selecting 1-3 kVA UPS for edge and small server rooms.

Document contents

  1. Product snapshot
  2. Features
  3. Model selection guide
  4. Battery runtimes
  5. Rear view and options

Publication details

Authors
Xtreme Power Conversion
Publisher
Xtreme Power Conversion
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Xtreme Power Conversion Xtreme P91g 1–3 kVA model selection guide, revision 9/15/26, p.2. Xtreme Power Conversion. https://www.xpcc.com/wp-content/uploads/P91g-1-3kVA-Flyer.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.