Rolls-Royce expands mtu product range with Kinolt uninterruptible power supply systems

Rolls-Royce

Rolls-Royce Power Systems markets the flywheel dynamic UPS products of Kinolt, acquired in 2020, as mtu Kinetic PowerPacks from 1 February 2021; the system combines UPS and emergency generator functions.

On this page

Overview

Rolls-Royce's press release of 2 February 2021 announces that the mtu brand of its Power Systems business now includes uninterruptible power supply (UPS) systems. Kinolt S.A. of Liège, Belgium, acquired in July 2020, was renamed Rolls-Royce Solutions Liège SA on 1 February 2021 and became a competence centre for dynamic UPS. Its products are sold as mtu Kinetic PowerPacks.

The mtu Kinetic PowerPack combines flywheel energy storage with modern diesel engines to provide UPS and emergency power functions in one system. The release says it provides continually high energy quality, eliminates 'parasitic' effects on the power grid and, on grid failure, safeguards supply without loss of power or voltage. Target sites are data centres, hospitals and sensitive industrial processes.

The release notes that Kinolt was founded in 1984 as Euro-Diesel and is among the market leaders in dynamic uninterruptible power supplies. The sales and service organisation is to be incorporated gradually into the Power Systems service organisation. The text carries no technical data such as capacity, efficiency or runtime; its subject is the product range and corporate integration.

Key points

  1. Rolls-Royce acquired Kinolt S.A. in July 2020; the company became Rolls-Royce Solutions Liège SA on 1 February 2021.
  2. Products are marketed as mtu Kinetic PowerPack from 1 February 2021.
  3. Kinolt was founded in 1984 as Euro-Diesel; based in Liège, Belgium.
  4. The system combines flywheel energy storage with a diesel engine: UPS and emergency power in one solution.
  5. Target sites: data centres, hospitals, sensitive industrial processes.
  6. Stated benefit: supply without loss of power or voltage on grid failure and no parasitic effects on the grid.
  7. Rolls-Royce Power Systems is headquartered in Friedrichshafen with around 10,000 employees.

Using it in design

  • When considering a dynamic, flywheel UPS in place of a static battery UPS, compare battery room needs, replacement interval and fire load.
  • For a combined UPS and generator system, request capacity, fuel, exhaust and footprint data from the manufacturer for the project; the release gives no numbers.
  • At sites with poor grid quality, write the claimed removal of parasitic grid effects as a measurement and commissioning criterion.
  • In supplier and service selection, assess integration into the mtu service organisation.

Who should read it

Data centre and critical facility designers evaluating dynamic UPS and combined UPS-generator solutions.

Document contents

  1. Announcement and range expansion
  2. mtu Kinetic PowerPack function
  3. Kinolt history and about Rolls-Royce

Publication details

Authors
Rolls-Royce
Publisher
Rolls-Royce
Year
Year not stated
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Rolls-Royce Rolls-Royce expands mtu product range with Kinolt uninterruptible power supply systems. Rolls-Royce. https://rolls-royce.com/media/press-releases/2021/02-02-2021-rr-expands-mtu-product-range-with-kinolt-uninterruptible-power-supply-systems.aspx

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.