BSB Power HRL Series High-Rate Long-Life VRLA Battery (12 V, 300-900 W/cell)
Original title BSB HRL Series 12V High Rate Battery: official technical table
BSB Power
BSB Power HRL series 12 V high-rate long-life battery: 300-900 W per cell at 15 minutes (1.67 V), 12-year float design life, -40 to 50 °C and 5-year warranty, for data-centre and high-rate UPS use.
On this page
Overview
The product page presents BSB Power's HRL (High Rate & Long life) series as a battery designed for important high-rate discharge applications. Strong grids and specially designed active material give stable performance at high power and current. The maker states 30% more power at 15 minutes backup, a 12-year design life on float, low internal resistance from optimised plates, an operating range of -40 to 50 °C and low self-discharge. The series is recommended for data centres, high-rate UPS/EPS systems and switchgear applications; a 5-year warranty is provided.
The model table lists thirteen 12 V models, HRL12-300W to HRL12-900W, with values in watts per cell at 1.67 V and 15 minutes. For example the HRL12-300W is 260 x 168 x 211 mm (214 mm total height) with an M6 terminal; the HRL12-500W is 407 x 172 x 236 mm with M8; the HRL12-900W is 499 x 259 x 221 mm (225 mm total) with M8. Intermediate models are rated 350, 400, 450, 560, 620, 660, 700, 750, 800 and 850 W.
The page covers only the high-rate series and its dimension table; discharge curves, weights and charge parameters are not on it. The same site also lists front-access gel, FAG, lithium and energy storage products; this document concerns the HRL product only.
Key points
- 13 models from HRL12-300W to HRL12-900W; values at 15 min, 1.67 V/cell.
- 30% more power at 15 minutes backup (maker's statement).
- 12-year float design life; 5-year warranty.
- Operating temperature -40 to 50 °C.
- HRL12-300W: 260 x 168 x 211 mm; M6 terminal.
- HRL12-500W: 407 x 172 x 236 mm; M8 terminal.
- HRL12-900W: 499 x 259 x 221 mm (225 mm total); M8 terminal.
- Target uses: data centre, high-rate UPS/EPS, switchgear.
Using it in design
- Size the data-centre UPS battery string with the 15-minute W-per-cell value: divide load watts by cell count and compare with the table.
- Take each model's length x width x height from the table for rack layout (260-532 mm length).
- Carry the terminal type (M6/M8) into busbar and cable connection design.
- Request the maker's model datasheet for weights and discharge curves.
Who should read it
Electrical designers sizing data-centre UPS battery strings.
Document contents
- HRL series description and features
- Model table: code, voltage, power, dimensions, terminal
Publication details
- Authors
- BSB Power
- Publisher
- BSB Power
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
BSB Power BSB HRL Series 12V High Rate Battery: official technical table. BSB Power. https://www.bsbpower.com/BatteryProducts_260.html
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.