Keheng LiFePO4 Battery Catalog: SLA Replacement Batteries 12.8-51.2 V
Original title Keheng SLA Battery Catalog: UPS Battery Backup technical specifications
Keheng New Energy
Keheng New Energy's catalogue lists 12.8, 25.6 and 51.2 V LiFePO4 batteries that replace lead-acid (SLA) units, rated 50-300 Ah with over 6000 cycles.
On this page
Overview
Although the catalogue title refers to SLA batteries, the content presents lithium iron phosphate (LiFePO4) batteries designed as drop-in replacements for sealed lead-acid units. Keheng has produced batteries since 2008. The document contains the features of the ABS-cased batteries, a performance summary comparing them with SLA, and technical tables; the comparison covers headings such as cycling, depth of discharge, temperature behaviour, weight and standby life.
The tables cover 14 models. The 12.8 V series is rated 50, 85, 100, 125, 146, 200, 280 and 300 Ah (640 Wh to 3,840 Wh). The 25.6 V series is 100, 120, 200 and 280 Ah, and the 51.2 V series is 50 and 100 Ah (2,560 and 5,120 Wh). All models have a cycle life of at least 6000 cycles at 80% depth of discharge; charge temperature is 0-45 °C, discharge temperature -20 to 55 °C and storage temperature -20 to 60 °C.
The batteries have an integrated smart BMS with overcharge, over-discharge, temperature, current, voltage, short-circuit and reverse-connection protection. Bluetooth, WiFi and LCD with real-time app monitoring, a heating function and an on/off button are optional. A sheet-metal supported internal structure holds the cells better and improves heat dissipation. Up to 4 batteries can be connected in series (maximum system voltage 48 Vdc) and up to 15 in parallel. The document is a general-purpose SLA-replacement catalogue rather than a data-centre UPS battery catalogue; stated applications are solar energy storage, off-grid backup, marine, golf carts and AGVs. Certifications are UN38.3, MSDS and CE. Cabinet energy or load-time relationships are not given in the document.
Key points
- 14 models: 12.8 V (8 models, 50-300 Ah), 25.6 V (4 models, 100-280 Ah), 51.2 V (2 models, 50 and 100 Ah).
- Energy ranges from 640 Wh (12.8 V 50 Ah) to 7,168 Wh (25.6 V 280 Ah).
- Cycle life at least 6000 cycles at 80% depth of discharge.
- Operating voltage 10.4-14.6 V on the 12.8 V model; charge 0-45 °C, discharge -20 to 55 °C.
- 12.8 V 100 Ah model: standard charge 20 A, maximum continuous discharge 100 A; weight 10 kg.
- Flame-resistant ABS case; size from 229×138×210 mm (50 Ah) to 640×245×220 mm (25.6 V 280 Ah).
- Integrated BMS: overcharge, over-discharge, temperature, current, voltage, short-circuit and reverse-connection protection.
- Series up to 4 batteries (48 Vdc system), parallel up to 15 batteries.
- Certifications: UN38.3, MSDS, CE; IP67 waterproof option.
Using it in design
- Before using them as UPS batteries, ask the manufacturer to confirm UPS compatibility and charge profile; the document targets general-purpose use.
- Compare the series and parallel limits (4 series, 15 parallel) with the voltage and capacity target of a system built from them.
- Because the lithium charge temperature has a 0 °C lower limit, design battery-room temperature to that limit.
- Use the Wh values for energy and runtime calculations; the document gives no load-time relationship.
- Match BMS communication options (CAN, Bluetooth, WiFi) to the monitoring system requirement.
Who should read it
Designers evaluating lithium alternatives to lead-acid backup batteries, and engineers building small-scale backup power systems.
Document contents
- Features and advantages
- Battery management system
- SLA versus lithium performance comparison
- Technical specification: 12.8 V series
- Technical specification: 25.6 V and 51.2 V series
- Configuration upgrades and options
- Series and parallel connection applications
Publication details
- Authors
- Keheng New Energy
- Publisher
- Keheng New Energy
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Keheng New Energy Keheng SLA Battery Catalog: UPS Battery Backup technical specifications. Keheng New Energy. https://www.lithiumbatterytech.com/KH-SLA-Battery-Catalog.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.