Tianneng lead-acid catalogue: TNG General Purpose GEL Battery
Original title Tianneng lead-acid catalogue, TNG General Purpose GEL Battery, printed pp.39–40
Tianneng
In the Tianneng catalogue the TNG series offers six 12 V gel batteries from 90 to 250 Ah (C10) with a design life above 12 years and deep-cycle capability; the TN AGM series runs 4.5-250 Ah with 5-8 years.
On this page
Overview
Tianneng is a Chinese energy group producing batteries since 1986, with 18 production bases and reported 2024 annual sales of $11.0 billion. The lead-acid brochure presents motive power, SLI and energy storage products; UPS and EPS applications fall under the TN, TNG and TNC series in the storage section. For data-centre design the most relevant part of this document is the TNG general purpose gel battery pages.
The TNG series combines nano gel electrolyte with an AGM structure. The catalogue says the range offers a design life above 12 years and very high deep-cycling capability, suited to outdoor telecom, renewable energy systems and harsh environments. There are six models, TNG12-90, -100, -120, -150, -200 and -250; all are 12 V, with capacity given as C10 at 1.80 V per cell and 25 °C of 90, 100, 120, 150, 200 and 250 Ah.
Dimensions are listed as length, width and height: for example 330 x 172 x 214 mm (total height 221.5 mm) for the TNG12-100 and 520 x 268 x 220 mm (total 225 mm) for the TNG12-250. Terminal type is I3 or I7. The manufacturer also lists claims of better charge acceptance, low-temperature capacity and cycle life; the test conditions for these are not described in the document.
The same catalogue lists the TN general purpose AGM series in 46 models, 12 V from 4.5 to 250 Ah plus 2 V cells from 100 to 3000 Ah (C10), with a design life of 5 to 8 years. Cell, monobloc and cabinet levels are kept as in the source; cabinet energy and load-time relations are not in the document.
Key points
- TNG general purpose gel battery: 6 models, 12 V, C10 capacity 90, 100, 120, 150, 200 and 250 Ah (1.80 V per cell, 25 °C).
- Design life above 12 years for TNG; 5-8 years for the TN AGM series.
- TNG12-100 measures 330 x 172 x 214 mm and TNG12-250 measures 520 x 268 x 220 mm; terminal I3 or I7.
- The TN AGM series includes 46 models: 12 V from 4.5 to 250 Ah and 2 V from 100 to 3000 Ah.
- The TN series claims over 98% 28-day capacity retention, 20% better charge acceptance and 50% better corrosion resistance.
- Applications include UPS/EPS, telecommunications, electric power, solar and wind energy.
- Tianneng has produced since 1986, with 18 production bases and over 4000 patents.
Using it in design
- When comparing capacities, separate C10 and C20 based values; in the TN series some models quote C10 and others C20, and the difference changes the result.
- For UPS battery-room layout use the model's length, width and total height and the terminal type.
- Have the 12-year TNG design life verified against ambient temperature and depth of discharge with a life curve; the document does not give one.
- Do not derive cabinet energy or autonomy from the document; request load-time tables from the manufacturer.
Who should read it
Electrical designers selecting UPS battery systems and battery purchasing teams.
Document contents
- Company profile
- Milestones
- Energy storage solution
- TN series (general purpose AGM battery)
- TNG series (general purpose GEL battery)
- TNC series (lead carbon battery)
Publication details
- Authors
- Tianneng
- Publisher
- Tianneng
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Tianneng Tianneng lead-acid catalogue, TNG General Purpose GEL Battery, printed pp.39–40. Tianneng. https://www.tiannengglobal.com/uploadfile/file/20251120/1763617012898411.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.