Upower UP-HR Series: High rate AGM specifications
Upower
Upower UP-HR is a high-rate AGM battery series for short autonomy, with a design life of 10 years or more at 20 °C and 2 V, 6 V and 12 V models (for example UP-HR100-12: 104 Ah at 10 hours, 330 mm long).
On this page
Overview
The Upower UP-HR page describes a high-rate AGM battery series presented as the best solution for high energy needs at short autonomies. The manufacturer says plate design and curing give a very low internal resistance and a design life of 10 years or more at 20 °C. Main uses are UPS, emergency power supply, electric tools, mechanical or electrical starting systems and emergency lighting.
The specification table lists 2 V, 6 V and 12 V models. For each it gives nominal voltage, 10-hour capacity, length, width, height, total height (mm and inches), weight and terminal type. Examples: UP-HR100-6 is 104 Ah, 195 x 170 x 206.5 mm and 15.6 kg; UP-HR2.2-12 is 2.28 Ah, 178 x 35 x 60 mm and 1.0 kg; UP-HR65-12 is 67.4 Ah, 348 x 167 x 178 mm and 21.0 kg.
The 2 V model UP-HR400-2 is rated not by capacity but as 1000 W at the 15-minute rate to 1.67 V at 25 °C; it measures 170 x 150 x 330 mm, weighs 19 kg and has an F10 (M8) terminal. The large 12 V models reach UP-HR100-12 at 104 Ah (10 hour) and 330 mm length. Capacities in the table are 10-hour values, and load-time tables and cabinet energy are not in the document.
Key points
- UP-HR is a high-rate AGM series for short autonomy; design life 10 years or more at 20 °C.
- Capacity is given as a 10-hour value; models are 2 V, 6 V and 12 V.
- UP-HR400-2: 1000 W at the 15-minute rate to 1.67 V at 25 °C; 170 x 150 x 330 mm; 19 kg; F10 (M8) terminal.
- UP-HR100-6: 104 Ah; 195 x 170 x 206.5 mm; 15.6 kg; terminal T6.
- UP-HR65-12: 67.4 Ah; 348 x 167 x 178 mm; 21.0 kg; terminal T6.
- UP-HR2.2-12: 2.28 Ah; 178 x 35 x 60 mm; 1.0 kg; terminal T1.
- Uses: UPS, emergency power, electric tools, starting systems, emergency lighting.
Using it in design
- For UPS autonomy of several minutes use the 15-minute W rating (as for UP-HR400-2); the 10-hour Ah value alone is not enough for high-rate discharge.
- Reflect the 10-year design life at 20 °C in the replacement plan, reduced for ambient temperature.
- For rack layout use length, width, total height and terminal type.
- Request load-time tables and cabinet energy from the manufacturer; the page does not give them.
Who should read it
Engineers designing UPS battery systems and battery purchasing teams.
Document contents
- UP-HR series description
- Main uses
- Specification table (2 V, 6 V, 12 V)
Publication details
- Authors
- Upower
- Publisher
- Upower
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Upower Upower UP-HR Series: High rate AGM specifications. Upower. https://www.upowerbatteries.com/up_hr.html
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.