Technical guideFree to read2025

Intelbras DNB 6/10 kVA-220V-RT User Manual (02-25)

Original title Intelbras DNB 6/10kVA-220V-RT user manual 02-25, pp.6–7

Intelbras

A Portuguese-language Intelbras manual that gives the technical specifications, external battery modules and installation information of the 6 and 10 kVA, 220 V, single-phase, double-conversion rack/tower DNB UPS models.

On this page

Overview

The manual presents the DNB series as pure-sine double-conversion (on-line) rack/tower UPS designed for commercial and industrial use. It states the units are designed for data processing equipment, servers and IT devices, and should not be used to power medical monitoring or life-support equipment or equipment containing motors. There are two models: the DNB 6kVA-220V-RT (6 kVA / 6 kW, code 4822047) and the DNB 10kVA-220V-RT (10 kVA / 10 kW, code 4822052). Input is 220/230/240 V (factory 220 V), 50/60 Hz (factory 60 Hz), connected phase-neutral-earth or phase-phase-earth.

The specification table gives input current of 27.3 A and 45.5 A, an input voltage range of 175-288 V above 50% load and 120-288 V below, input power factor above 0.99 and input current THD below 3% at linear load. Output power factor is 1.0, voltage regulation plus or minus 1%, crest factor 3:1, and voltage THD below 1% at linear load and below 2% at non-linear load. Efficiency reaches 94% in double conversion and 97% in eco and bypass modes. Overload tolerance is 10 minutes at 105-110%, 1 minute at 110-125% and 30 seconds at 126-150%, after which the unit moves to bypass; transfer time from mains to battery and bypass is 0 ms.

The units have no internal batteries. The 6 kVA model works with the 192 Vdc MB 1607-192V-RT module (16 x 12 V/7 Ah VRLA) and the 10 kVA model with the 240 Vdc MB 2009-240V-RT module (20 x 12 V/9 Ah VRLA); up to 5 external battery banks can be connected. Charge current is adjustable from 1 to 5 A (factory 1 A for 6 kVA, 2 A for 10 kVA), and DOD and float voltage are adjustable (default 10.5 V and 13.5 V per battery). N+X paralleling is possible with up to 4 units; interfaces are RS232, USB and SNMP.

Physical data: maximum dimensions 440 x 580 x 88 mm, weight 12 kg and 14 kg, operating temperature 0-40 degrees C, humidity 0-95% non-condensing, noise below 60 dB, maximum heat dissipation 1230 and 2050 BTU/h. Output power derates above 1000 m: 95% at 1500 m, 91% at 2000 m, 82% at 3000 m and 67% at 5000 m. As an installation example, 6 mm2 conductor and a 40 A breaker are given for the 6 kVA model and 10 mm2 and 63 A for the 10 kVA model. The document contains no unpublished physical or performance values; model power is limited to the two classes in the document.

Key points

  1. Two models: DNB 6kVA-220V-RT (6 kVA / 6 kW) and DNB 10kVA-220V-RT (10 kVA / 10 kW); codes 4822047 and 4822052. No model is derived from a continuous range.
  2. Double-conversion on-line, pure sine; input power factor >0.99, input THDi <3% (linear load), output power factor 1.0.
  3. Input voltage range 175-288 V for load >50%, 120-288 V for <50%; input current 27.3 A (6 kVA) and 45.5 A (10 kVA).
  4. Efficiency: up to 94% in double conversion, up to 97% in eco and bypass modes.
  5. Overload: 10 min at 105-110%, 1 min at 110-125%, 30 s at 126-150%; then moves to bypass. Transfer time 0 ms.
  6. No internal battery; for 6 kVA 192 Vdc / 16 x 12 V 7 Ah (MB 1607-192V-RT), for 10 kVA 240 Vdc / 20 x 12 V 9 Ah (MB 2009-240V-RT); up to 5 external banks.
  7. Charge current 1-5 A (factory 1 A and 2 A); default DOD 10.5 V and float 13.5 V per battery.
  8. Up to 4 units in N+X parallel; RS232, USB, SNMP interfaces.
  9. Dimensions 440 x 580 x 88 mm; weight 12 kg (6 kVA) and 14 kg (10 kVA); operating temperature 0-40 degrees C; noise below 60 dB.
  10. Derating above 1000 m: 95% at 1500 m, 91% at 2000 m, 82% at 3000 m, 74% at 4000 m, 67% at 5000 m.

Using it in design

  • In the catalogue use only the two power classes (6 and 10 kVA) in the document and the mapped external battery modules; do not create models for intermediate ratings.
  • Match the external battery module to the UPS: 192 Vdc for 6 kVA, 240 Vdc for 10 kVA; calculate runtime against the 36 Ah maximum bank capacity and the 5-bank limit.
  • For the supply, take 6 mm2 / 40 A for the 6 kVA model and 10 mm2 / 63 A for the 10 kVA model as a starting example and verify with NBR 5410 or local code.
  • If altitude exceeds 1000 m, apply the derating table in the document and add the heat dissipation (1230 and 2050 BTU/h) to the cooling load.
  • If the load is medical life support or motor equipment, state this product's use restriction in the specification.

Who should read it

Engineers selecting single-phase rack/tower UPS for small and medium IT loads and teams preparing a product catalogue.

Document contents

  1. Technical specifications
  2. Electromagnetic compatibility
  3. Installation and installation of external battery modules
  4. Operation and checking UPS status
  5. Frequently asked questions: fault and alert tables
  6. Autonomy
  7. Warranty

Publication details

Authors
Intelbras
Publisher
Intelbras
Year
2025
Document number
02-25
Document language
Portuguese
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

Intelbras (2025). Intelbras DNB 6/10kVA-220V-RT user manual 02-25, pp.6–7. Intelbras. 02-25. https://backend.intelbras.com/sites/default/files/2026-01/Manual_DNB_6KVA_10kVA_220VRT_02-25_site.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.