IntelliPower IntelliShield Rugged UPS Family Specifications
Original title IntelliPower IntelliShield Rugged UPS family specifications
IntelliPower
IntelliPower's IntelliShield page presents 3 kW and 5 kW double-conversion rugged UPS models operating from -20 to +50 °C, with 47-440 Hz input and THD below 5%.
On this page
Overview
The page summarises the IntelliShield rugged UPS family, designed to military and industrial standards. The family has two models, 3 kW and 5 kW, on a common architecture built for harsh environments with minimal cooling. Both models operate from -20 °C to +50 °C, and custom configurations extend this to +55 °C.
The 3 kW model delivers 3 kVA/3 kW in a 2U chassis with an integrated hot-swap battery drawer; its input range is 108-264 VAC and typical efficiency is 85%. The 5 kW model delivers 5 kVA/5 kW on a 208-240 VAC (±10%) input, uses external 2U battery packs only, and reaches typical efficiency up to 89%. Both accept 47-440 Hz input frequency and have output THD below 5%.
Both models use a true online double-conversion topology with zero transfer time during input disturbances. Battery chemistry can be VRLA or lithium iron phosphate (LiFePO4), a choice weighed on cost, weight, cycle life and depth of discharge. Input and output connectors can be MIL-spec circular connectors or terminal strips. SNMP and RS-232 interfaces are standard for monitoring and control. The page states that the design meets IEC 62040, RoHS 3, CE and applicable military environmental and EMI standards. It is a product introduction; detailed dimension, weight and runtime tables are in the technical resources.
Key points
- Two models: 3 kVA/3 kW (2U, integrated hot-swap battery drawer) and 5 kVA/5 kW (external 2U battery packs only).
- Operating temperature -20 to +50 °C; up to +55 °C in custom configurations.
- Input: 108-264 VAC on the 3 kW model; 208-240 VAC (±10%) on the 5 kW model; frequency 47-440 Hz.
- Output THD below 5% on both models.
- Typical efficiency: 85% on the 3 kW model, up to 89% on the 5 kW model.
- Topology: true online double conversion, zero transfer time.
- Battery chemistry: VRLA or LiFePO4.
- Connectors: MIL-spec circular or terminal strips; interfaces: SNMP and RS-232.
- Compliance: IEC 62040, RoHS 3, CE, military environmental and EMI standards.
Using it in design
- Use the wide temperature range (-20/+50 °C) in containerised, mobile or field data rooms with limited air conditioning.
- On systems fed by generators or mobile sources, confirm compatibility with the 47-440 Hz input frequency.
- Choose battery chemistry (VRLA or LiFePO4) on weight, life and depth-of-discharge criteria.
- Carry the lower efficiency (85-89%) into heat-load calculations and chassis airflow.
- Select the connector type (MIL-spec or terminal strip) to match cabling and field equipment.
Who should read it
Designers selecting UPS for harsh environments in defence, transport, oil and gas, and edge data-centre applications.
Document contents
- IntelliShield Rugged UPS family
- Features: rugged design, scalable power, input voltage and frequency range, low THD, battery chemistry options, efficiency, topology, connectors, monitoring, compliance
- Why choose IntelliShield
- Extended power backup
Publication details
- Authors
- IntelliPower
- Publisher
- IntelliPower
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
IntelliPower IntelliPower IntelliShield Rugged UPS family specifications. IntelliPower. https://www.intellipower.com/intellishield-rugged-ups
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.