Marathon Power Vault High Power 230V Tower UPS VTWP Model Specifications
Original title Marathon Power Vault High Power 230V tower VTWP model specifications
Marathon Power
Marathon Power Vault High Power VTWP, 1 to 10 kVA, is a true online double-conversion tower UPS with 0.9 output power factor, THD below 2.5% and UL certification, in six models from 900 W to 9000 W.
On this page
Overview
The Marathon Power Vault High Power series is a tower UPS family with true online double-conversion topology, integral automatic bypass and 0.9 output power factor. The manufacturer says it delivers more real power to sensitive loads and protects connected equipment against voltage fluctuation, spikes, surges, noise, extended under- and over-voltage, harmonics and frequency variation. The sine-wave output has THD below 2.5%; an EPO port, High Efficiency (HE) and free-run modes, cold start and gen-set compatibility mode are included. The UL certificate number is E316102.
The VTWP models are 1000 VA / 900 W, 1500 VA / 1350 W, 2000 VA / 1800 W, 3000 VA / 2700 W, 6000 VA / 5400 W and 10000 VA / 9000 W. Input current runs from 4.7 A to 48 A. The 1 to 3 kVA models use a 6 ft power cord (IEC C14 10 A or C20 16 A) and IEC C13/C19 output sockets; the 6 and 10 kVA models are hardwired (6-position terminal blocks, 57 A, M5 bolt).
The battery side uses sealed lead-acid modules of 7.2 Ah/12 V or 9 Ah/12 V, with 3 to 20 internal battery cartridges per model (for example 3 for 1000 VA and 20 for 6000 and 10000 VA). Weight runs from 13.5 kg to 96 kg, and the 6 kVA unit measures 257 x 590 x 570 mm. Application fields are medical imaging, industrial automation, laboratory and OEM equipment. The source is the manufacturer's product page.
Key points
- Topology: true online double conversion with integral automatic bypass; output power factor 0.9.
- Six models: 1000 VA / 900 W, 1500 VA / 1350 W, 2000 VA / 1800 W, 3000 VA / 2700 W, 6000 VA / 5400 W, 10000 VA / 9000 W.
- Input currents: 4.7, 7, 9.4, 14.1, 28.9 and 48 A.
- Sine output THD below 2.5%; EPO port, HE and free-run mode, cold start.
- UL certificate E316102.
- Battery: sealed lead-acid 7.2 Ah or 9 Ah / 12 V; 3 to 20 internal cartridges.
- 6 and 10 kVA models: hardwired input and 57 A, M5 output terminal blocks.
- Weight 13.5 kg (1 kVA) to 96 kg (10 kVA).
Using it in design
- With a 0.9 power factor, verify capacity in W; the 10 kVA model gives 9 kW.
- For 6 and 10 kVA models, note the hardwired input drawing up to 48 A when selecting feeder cable and protection.
- Where the gen-set compatibility mode and cold start will be used, confirm generator sizing with the manufacturer.
- Add accessories such as the SNMP card and AS-400 relay card to the specification for monitoring.
- Take runtimes from the separately published back-up time tables.
Who should read it
Engineers selecting tower UPS units for medical, industrial and laboratory loads.
Document contents
- Product overview and certifications
- Key features
- Applications
- VTWP model specifications
- Battery specifications
- Downloads
Publication details
- Authors
- Marathon Power
- Publisher
- Marathon Power
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
Marathon Power Marathon Power Vault High Power 230V tower VTWP model specifications. Marathon Power. https://www.marathon-power.com/vault-high-power-series-ups/p/203v-1kva-10kva-tower-ups
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.