NHS NSYS Serie K 40 kVA 380 V Three-Phase Online UPS
Original title NHS NSYS Série K 40kVA380V official product page
NHS
NHS NSYS Serie K 40 kVA, 380 V three-phase online UPS: 384 V (±192 V) battery bus of 16+16 12 V batteries, RS485 and dry contact, 4 ms transfer to bypass, certified to IEC 62040-1/-2/-3.
On this page
Overview
The page presents a 40 kVA three-phase online UPS from the NSYS Serie K family of the Brazilian maker NHS. The product code is 92.U3.K40460, and the unit is supplied without batteries (S.Bat), so the external battery string is sourced separately. Input and output nominal voltage is 380 V phase to phase.
The battery configuration is 16+16 12 V blocks and the operating voltage is stated as 384 V (±192 V). The unit measures 840x358x1250 mm and weighs 92 kg without batteries. Input and output terminal blocks, a dry contact and quick connection are provided; there is an RS485 interface but no RS232 or USB. Transfer time from battery mode to bypass mode is 4 ms.
The product meets EN IEC 62040-1, EN IEC 62040-2 and EN IEC 62040-3. The page carries no autonomy data for this model; a technical manual and a datasheet are offered as downloads. Runtime, efficiency and heat-load figures therefore come from the manufacturer's documents.
Key points
- Rating 40 kVA, 380 V phase-to-phase input and output, three-phase online topology.
- Battery bus 384 V (±192 V), 16+16 12 V batteries; the unit is supplied without batteries.
- Size 840x358x1250 mm, weight 92 kg without batteries.
- Transfer time from battery mode to bypass mode is 4 ms.
- Communication: RS485 present; RS232 and USB absent; dry contact and EPO input available.
- Certifications: EN IEC 62040-1, EN IEC 62040-2, EN IEC 62040-3.
- Terminal block input and output connection, with quick connection support.
Using it in design
- Match the 16+16 block, 384 V bus to the external battery cabinet and the autonomy calculation, since the unit ships without batteries.
- With RS485 only, check whether the monitoring system needs a Modbus/RS485 gateway.
- Compare the 4 ms bypass transfer with the critical load's tolerance curve.
- Carry the 840x358x1250 mm size and 92 kg weight into the layout and floor loading plan.
Who should read it
Electrical designers and procurement engineers selecting mid-range three-phase UPS.
Document contents
- Description
- Technical information
- Product specifications
- Options
- Autonomy
- Downloads
Publication details
- Authors
- NHS
- Publisher
- NHS
- Year
- Year not stated
- Document language
- Portuguese
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
NHS NHS NSYS Série K 40kVA380V official product page. NHS. https://nhs.com.br/produto/nobreak-nsys-serie-k-online-trifas-40kva-380v-380v-s-bat-rs485-epo-cont-seco-bypass/
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.