OPTI-UPS DS-E 1-10K PF0.9 datasheet (2020)

Original title OPTI-UPS DS-E 1–10K PF0.9 datasheet (2020)

OPTI-UPS

A 2020 datasheet for OPTI-UPS's DS-E series of single-phase, double-conversion, sine-wave online UPS models (1, 2, 3, 6 and 10 kVA at power factor 0.9), with features and a technical table.

On this page

Overview

The datasheet presents the DS-E series as a high-performance sine-wave online UPS designed for network computers and small precision instruments, with uses listed in finance, communication, insurance, railway, medical, mining and enterprise, and particular suitability for poor electrical environments. Features include microprocessor control, input power factor correction, a 50/60 Hz frequency converter mode, eco mode, EPO, generator compatibility and a smart battery charger.

Five models are listed: DS1000E (1000 VA / 900 W), DS2000E (2000 VA / 1800 W), DS3000E (3000 VA / 2700 W), DS6000E (6000 VA / 5400 W) and DS10000E (10000 VA / 9000 W). Topology is true online double conversion, battery-mode output is pure sine and voltage regulation is ±1 percent. AC-mode efficiency is 88, 89, 90, 92 and 93 percent by model, and 96 percent in eco mode. Harmonic distortion is 3 percent THD or less on linear load and 6 percent or less on non-linear load.

Transfer times are 0 ms from AC to DC, 4 ms from inverter to bypass and 8-10 ms from eco to battery mode. On overload the unit shuts down after 10 s at 105-130 percent and after 5 s at 150 percent. Battery configuration varies: 24 V (12 V 9 Ah x 2), 48 V (x 4), 72 V (x 6) and 192 V (x 16) for the 6 and 10 kVA models. Recharge to 90 percent is typically under 3 hours at 2 A. Communication is RS232 and USB, with SNMP management.

Operating temperature is 0-45 C, humidity 0-95 percent non-condensing, and noise is 50 dBA (smaller models) to below 55 dBA at 1 m. Standard and long-backup types differ in size and weight; for example the DS1000E standard type is 145 x 282 x 220 mm and 9.8 kg, and the long-backup type is 4.4 kg. Only published values can be used; no model can be derived from a continuous range.

Key points

  1. Five discrete models: 1, 2, 3, 6 and 10 kVA (900, 1800, 2700, 5400 and 9000 W; power factor 0.9).
  2. True online double conversion; pure sine in battery mode, ±1 percent regulation, crest factor 3:1.
  3. AC-mode efficiency is 88, 89, 90, 92 and 93 percent respectively; eco mode 96 percent.
  4. Transfer: AC to DC 0 ms, inverter to bypass 4 ms, eco to battery mode 8-10 ms.
  5. THD: 3 percent on linear load, 6 percent or less on non-linear load.
  6. Overload: shutdown after 10 s at 105-130 percent, after 5 s at 150 percent.
  7. Battery: 24, 48, 72 V (2, 4, 6 blocks of 12 V 9 Ah) and 192 V (16 blocks) for 6 and 10 kVA; 90 percent recharge under 3 hours at 2 A.
  8. Input voltage range 160-280 V (220/230/240 V) for smaller models and 176-300 V for larger models.
  9. Operation 0-45 C, humidity up to 95 percent non-condensing; RS232, USB and SNMP.

Using it in design

  • Size loads in kW rather than kVA (for example 1 kVA = 900 W).
  • Select only among the five published models; do not derive intermediate models.
  • Check that the 8-10 ms eco-to-battery transfer suits the load hold-up time.
  • Assess backup time separately for standard and long-backup types, and take the size and weight difference into the layout.
  • Add SNMP and RS232/USB monitoring points to the network plan.

Who should read it

Designers selecting 1-10 kVA online UPS units for small and medium critical loads.

Document contents

  1. Introduction and features
  2. Specifications: input, output, efficiency, protection, battery, interface, environment, mechanical

Publication details

Authors
OPTI-UPS
Publisher
OPTI-UPS
Year
2020
Document language
English
Source type
Manufacturer
Access
Free to read
Licence
Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note

No document-specific redistribution permission was established. Bibliographic reference only.

Citation

OPTI-UPS (2020). OPTI-UPS DS-E 1–10K PF0.9 datasheet (2020). OPTI-UPS. https://opti-ups.com/FilesUpload/eM97462105/DS-E%201-10K%20PF0.9.pdf

All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.

Power design in SoSo CAD

Calculate supply paths, equipment loads and UPS failure scenarios as part of the design.

Single-line diagram in the SoSo CAD power and capacity workspace

Keep your reading list current

Once a month: new library sources, changes to Turkish regulations and upcoming data centre events.