POWERVAR Sinergy III Series Online UPS Brochure, 700-6000 VA
Original title POWERVAR Sinergy III Series UPS OEM brochure, p.2 (Gryphon-hosted)
POWERVAR
POWERVAR Sinergy III is a 700-6000 VA double-conversion true-sinewave UPS: tower or 19-inch rack, hot-swappable internal batteries, up to 8 hours of extended runtime, UL, cUL and CE listed.
On this page
Overview
The brochure presents the Sinergy III series as an online double-conversion UPS engineered for demanding applications. A universal rack/tower design, hot-swappable internal batteries and matching extended battery packs allow runtime up to 8 hours. Target applications are advanced computer peripherals, telecom electronics, data centres, control systems and VoIP/PBX systems.
Product sizes range from 700 VA to 6000 VA; output is true sinewave with controllable receptacles, UL, cUL and CE approvals and a two-year warranty. North American models are 120 V in and out: ACDEF700-11 (5.8 A), 1000-11 (8.3 A), 1500-11 (12.5 A), 2000-11 (16.7 A) and 3000-11 (25 A), sized 3.39 x 17.24 x 16.26 in to 3.39 x 17.24 x 26.95 in. International models are 200/208/220/230/240 V in and out: ACDEF2000-22, 3000-22 and 6000-22, the 6000 VA model being 5.14 in high (3U).
All models are 50/60 Hz. The brochure is a short product summary and gives no efficiency, overload, battery or autonomy detail.
Key points
- Range 700-6000 VA; online double conversion with true sine output.
- North America: ACDEF700-11, 1000-11, 1500-11, 2000-11, 3000-11 (120 V; 5.8-25 A).
- International: ACDEF2000-22, 3000-22, 6000-22 (200-240 V, 50/60 Hz).
- Configurable as tower or 19-inch rack; hot-swappable internal batteries.
- With matching external battery packs, runtime up to 8 hours.
- Controllable receptacles; UL, cUL and CE approvals; two-year product warranty.
- Dimensions H x W x D: 3.39 x 17.24 x 16.26 in (700 VA) to 5.14 x 17.24 x 27.13 in (6000 VA).
Using it in design
- For in-rack installation, compare the roughly 2U (3.39 in) and 3U (5.14 in) heights and depths up to 27 in with the rack depth.
- Choose the 120 V (North America) or 200-240 V model by region.
- For autonomy up to 8 hours, calculate the number and weight of external battery packs.
- Use controllable receptacles to shed non-critical loads during backup in the load plan.
- Request the manufacturer's full datasheet for efficiency and heat load data.
Who should read it
Designers selecting small online UPS for telecom, VoIP and small data centre applications.
Document contents
- Overview and features
- North American models
- International models
Publication details
- Authors
- POWERVAR
- Publisher
- POWERVAR
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
POWERVAR POWERVAR Sinergy III Series UPS OEM brochure, p.2 (Gryphon-hosted). POWERVAR. https://www.gryphon-inc.com/PDF%20Literature/Sinergy%20III%20Series%20UPS%20Brochure.pdf
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.