RIWAS EPS-300/600/1000 official UPS model specification
RIWAS
RIWAS EPS-300/600/1000 are small 300, 600 and 1000 W sine-wave UPS models with a 12 Vdc external battery (AGM, gel or LiFePO4) and 8 ms transfer time.
On this page
Overview
The RIWAS product page lists the EPS-300, EPS-600 and EPS-1000 models in the UPS category with a portable power station keyword. The models are rated 300 W, 600 W and 1000 W. Input voltage is 140-280 VAC, 50/60 Hz; rated output voltage and no-load voltage are 220/230 VAC, 50/60 Hz. The output waveform is sine and the product uses a toroidal transformer.
UPS transfer time is 8 ms. Protections cover high voltage, low voltage, overload and short circuit. The display is a colour LCD and cooling uses a smart fan that starts automatically. Battery voltage is 12 Vdc and the external battery (not included) can be AGM, gel or LiFePO4. Maximum charge current is 10 A, 20 A and 30 A depending on the model.
Physical data: size 320 x 300 x 135 mm (D x W x H), net weight in horizontal position 7.2 kg (300 W), 9.9 kg (600 W) and 11.5 kg (1000 W). Storage and ambient temperature are -15 to 55 °C, noise is 60 dB or less and communication is USB. The page shows LiFePO4 batteries (BP-48150, BP-48200, BP-48314) as related products.
Key points
- Models: EPS-300 (300 W), EPS-600 (600 W), EPS-1000 (1000 W).
- Input 140-280 VAC, 50/60 Hz; output 220/230 VAC, 50/60 Hz, sine wave.
- UPS transfer time 8 ms; toroidal transformer.
- Protection: high voltage, low voltage, overload, short circuit.
- Battery voltage 12 Vdc; external battery AGM, gel or LiFePO4 (not included).
- Maximum charge current 10 A (300 W), 20 A (600 W), 30 A (1000 W).
- Size 320 x 300 x 135 mm; weight 7.2, 9.9 and 11.5 kg.
- Ambient and storage -15 to 55 °C; noise ≤ 60 dB; USB communication; colour LCD.
Using it in design
- For small network edge or control loads, match the 300-1000 W range to the load in watts; calculate the Ah needed for the 12 V battery bank from runtime and current.
- Compare the 8 ms transfer time with load interruption tolerance; for critical IT loads prefer an online UPS with shorter transfer.
- Check the external battery technology (AGM, gel or LiFePO4) and the maximum charge current (10-30 A) against battery capacity.
- The 140-280 VAC input window is an input to assessing suitability for sites with poor mains quality.
Who should read it
Designers and purchasing engineers looking for compact UPS for small edge and auxiliary loads.
Document contents
- Product description
- Specification table
- Related products
Publication details
- Authors
- RIWAS
- Publisher
- RIWAS
- Year
- Year not stated
- Document language
- English
- Source type
- Manufacturer
- Access
- Free to read
- Licence
- Copyright retained; citation only: the publisher’s terms apply to the original document
Original licence note
No document-specific redistribution permission was established. Bibliographic reference only.
Citation
RIWAS RIWAS EPS-300/600/1000 official UPS model specification. RIWAS. https://www.riwaspower.com/product_detail/30.html
All content and rights belong to the respective authors and publishers. SoSo CAD provides only the citation, its own summary and a link to the source, and is not responsible for the sources' content.